Sdiop-Pip27 - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

c. Select Initialize and format disk unit for each disk unit. When the new disk unit is initialized and
formatted, the display shows that the status is complete. This may take 30 minutes or longer. The
disk unit is now ready to be added to the system configuration.
This ends the procedure.
SDIOP-PIP27: For use by authorized service providers.
You were sent to this procedure with a unit reference code of 9051.
Note: For some storage I/O adapters, the cache card is integrated and not removable.
I/O card cache data exists for a missing or failed device. The possible causes are:
v One or more disk units have failed on the I/O card.
v The cache card of the I/O card was not cleared before it was shipped as a MES to the customer. In
addition, the service representative moved devices from the I/O card to a different I/O card before
performing a system IPL.
v The cache card of the I/O card was not cleared before it was shipped to the customer. In addition,
residual data was left in the cache card for disk units that manufacturing used to test the I/O card.
v The I/O card and cache card were moved from a different system or a different location on this system
after an abnormal power off.
v One or more disk units were moved either concurrently, or they were removed after an abnormal power
off.
Note: Any Function 08 power down (including from a D-IPL) is an abnormal power off!
1. If the system has logical partitions, perform this procedure from the logical partition that reported the
problem. To determine if the system has logical partitions, go to Determine if the system has logical
partitions before continuing with this procedure.
2. Access SST/DST by doing one of the following:
v If you can enter a command at the console, access system service tools (SST). See System
Service Tools (SST) in the iSeries Service Functions
v If you cannot enter a command at the console, perform an IPL to DST. See Performing an IPL to
DST in the iSeries Service Functions
v If you cannot perform a type A or B IPL, perform a type D IPL from removable media.
3. Did you perform a D IPL to get to DST?
v No: Access the Product Activity Log and display the SRC that sent you here. Press the F9 key for
address information. This is the I/O card address. Then, view the "Additional Information" to record
the formatted log information. Record the device types and serial numbers for those devices that
show a unit address of 0000 0000.
Continue with the next step.
v Yes: Access the Product Activity Log and display the SRC that sent you here. The direct select
address (DSA) of the I/O card is in the format BBBB-Cc-bb:
– BBBB = hexadecimal offsets 4C and 4D.
– Cc = hexadecimal offset 51
– bb = hexadecimal offset 4F
The unit address of the I/O card is hexadecimal offset 18C through 18F.
A formatted display of hexadecimal information for Product Activity Log entries is not available. In
order to interpret the hexadecimal information, see More Information from Hexadecimal Reports in
the iSeries Service Functions
that show a unit address of 0000 0000.
Continue with the next step.
206
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
information.
information.
. Record the device types and serial numbers for those devices

Advertisement