6. Install the wrap plug on the Fibre Channel IOA. After the wrap plug has been installed, wait 20
seconds and then check for a new 2765/2766/2787/5704 3140 SRC in the Product Activity Log. The
2765/2766/2787/5704 3140 SRC indicates that the port is active. Did a new 2765/2766/2787/5704
3140 SRC occur?
v Yes: Continue with the next step.
v No: Replace the Fibre Channel IOA. See symbolic FRU "FCIOA" on page 339 for further
instructions.
This ends the procedure.
7. Ask the customer whether the Fibre Channel IOA will attach devices now or whether the Fibre Channel
IOA is to be used at a later time. Is the Fibre Channel IOA intended to attach devices at this time?
v No: The wrap plug must be left installed on the Fibre Channel IOA when it is not in use. No further
service actions are required.
This ends the procedure.
v Yes: Unplug the wrap plug from the Fibre Channel IOA and wait until the 2765/2766/2787/5704
3120 SRC occurs. This may take up to 10 minutes. The failure has been isolated to the first link,
which includes any of the cables, junctions, etc. between the Fibre Channel IOA port and the first
Fibre Channel hub, switch, gateway or device. To continue diagnosis within this link, use existing
Fibre Channel service procedures, or contact your next level of support.
This ends the procedure.

HSLCTLR

For use by authorized service providers.
Follow the instructions for the model you are working on:
v Models 270, 800, 810, and 820 (See page 340)
v Models 830 and SB2 (See page 340)
v Models 840 and SB3 (See page 340)
v Models 825, 870, and 890 (See page 341)
Instructions for Models 270, 800, 810, and 820
The failing item is the system unit backplane in location MB1. For location information and links to the
remove and replace procedures, see Locations - Model 270, Locations - Models 800 and 810, or
Locations - Model 820.
Instructions for Models 830 and SB2
The failing item is the Network Interface Controller (NIC). Replace the following FRUs in order one at a
time until the problem is resolved. Be sure to IPL in SLOW OVERRIDE mode after each replacement.
1. Network interface controller (NIC) card in location M06.
2. Clock card in location M06A.
For location information and links to the remove and replace procedures, see Locations - Models
830/SB2 system unit with FC 9074 base I/O tower.
Instructions for Models 840 and SB3
The failing item is the Network Interface Controller (NIC). Replace the following FRUs in order one at a
time until the problem is resolved. Be sure to IPL in SLOW OVERRIDE mode after each replacement.
1. Network interface controller (NIC) card in location M17.
2. Clock card in location M19.
For location information and links to the remove and replace procedures, see Locations - Models
840/SB3 system unit with processor tower and FC 9079 base I/O tower.