Sicntrl - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

SICNTRL

For use by authorized service providers.
SICNTRL: Network Interface Controller (NIC).
The failing component is the Network Interface Controller (NIC).
Follow the instructions for the model you are working on:
v Models 270, 820, 830, 840, SB2, and SB3 (See page 448)
v Models 800 and 810 (See page 448)
v Models 825, 870, and 890 (See page 449)
Instructions for Models 270, 820, 830, 840, SB2, and SB3
Use the system model and the table below to determine the FRU containing the NIC. Exchange the FRU
indicated in the table below using the service information link.
Table 1. FRU containing the NIC for Models 270, 820, 830, 840, SB2, and SB3
System model, tower,
expansion unit, or
machine type
Model 270
Model 820
Models 830 and SB2
Models 840 and SB3
This ends the procedure.
Instructions for Models 800 and 810
Use the the table below to determine the FRU containing the NIC. Exchange the FRU indicated in the
table below using the service information link.
Table 2. FRU containing the NIC for Models 800 and 810
System model, tower,
expansion unit, or
machine type
Model 810 with processor
FC 7428, 7429, or 7430
Models 800 and 810
without processor features
7428, 7429, or 7430
448
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
Name of FRU to exchange FRU position
See Locations - Model 270. You will need the processor feature code (characters 5
through 8 of function 20 on the control panel).
Processor card
Network Interface Controller M06
Network Interface Controller M17
Name of FRU to exchange FRU position
System processor card
System unit backplane
M03
M02
MB1
Link to failing component
service information (CCIN,
location diagram, remove
and replace procedure).
See Locations - Model 820.
See Locations - Models
830/SB2 system unit with
FC 9074 base I/O tower.
See Locations - Models
840/SB3 system unit with
processor tower and FC
9079 base I/O tower.
Link to failing component
service information (CCIN,
location diagram, remove
and replace procedure).
See Locations - Models 800
and 810
See Locations - Models 800
and 810

Advertisement

Table of Contents
loading

Table of Contents