Cannot Automatically Perform An Ipl After A Power Failure - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

4. Does the Main Store Dump complete successfully (A1xx 300x displayed on the Monitor Partition Status
screen)?
v No: Continue with the next step.
v Yes: Work with the customer and your next level of support to collect the Main Store Dump and
APAR information. See the Getting started with server troubleshooting page in the Troubleshooting
and service topic in the iSeries Information Center.
a. Record the SRC information available in the Main Store Dump Summary.
b. Copy the main storage dump to media (see Working with Storage Dumps in the iSeries Service
Functions)
Copy the main storage dump to removable media or disk. Copying to disk is faster than copying
to most types of tape devices. To successfully copy to disk, you must have enough space
available in auxiliary storage to hold the main storage dump.
c. Continue with the next step.
5. Perform the following:
a. Power off the logical partition.
b. Power on the logical partition in Manual mode.
Does the logical partition IPL complete to DST?
v No: Continue with the next step.
v Yes: Go to "Use the service action log" on page 7.
This ends the procedure.
6. Does the logical partition stop with a reference code displayed on the Partition Status screen?
v No: Continue with the next step.
v Yes: Go to System Reference Codes and use the SRC information to correct the problem.
This ends the procedure.
7. Did a Missing Disk Units display appear?
v No: Continue with the next step.
v Yes: Go to "Use the service action log" on page 7.
This ends the procedure.
8. Did the Main Store Dump Manager display appear?
v No: Contact your next level of support.
This ends the procedure.
v Yes: Record the SRC information available in the Main Store Dump Summary (see iSeries Service
Functions
).
Then, go to System Reference Codes and use the SRC information to correct the problem.
This ends the procedure.

Cannot automatically perform an IPL after a power failure

For use by authorized service providers.
1. Normal or Auto mode on the control panel must be selected when power is returned to the system.
Is Normal or Auto mode on the control panel selected? See iSeries
v Yes: Continue with the next step.
v No: Select Normal or Auto mode on the control panel.
This ends the procedure.
2. Use the Display System Value command (DSPSYSVAL) to verify that the system value under
QPWRRSTIPL on the Display System Value display is equal to 1.
Is QPWRRSTIPL equal to 1?
v Yes: Continue with the next step.
30
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and Isolation
.
(TM)
Service Functions
.

Advertisement

Table of Contents
loading

Table of Contents