Uja34; Uje34; Uje35; Uje40 - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

UJA34

For use by authorized service providers.
The line configuration parameter that was identified as a possible problem can be changed by using the
WRKLIND command. Determine if the suspected configuration parameter is wrong and change if
necessary. Information about commands related to communications can be found in the following manuals:
v CL Programming, SC41-5721-03
v Communications Configuration, SC41-5401-00
Some software problems can be temporarily solved by changing the configuration parameter, even if the
original value was correct. Report this problem to your service representative if you use this temporary
change.

UJE34

For use by authorized service providers.
The error message may have been logged from a temporary error that is not caused by equipment failure.
This type of error message sometimes contains information about system performance.
See the original system message for cause and recovery information about the error.

UJE35

For use by authorized service providers.
The configuration parameter that was identified as a possible problem can be verified by displaying the
local area network line description with the DSPLIND command.
The line description was created by the CRTLINTRN, the CRTLINETH or the CRTLINDDI command. You
may need to review the appropriate command information to determine if the configuration parameter is
wrong.
For more information about commands related to communications, see the CL command finder in the
Programming, CL topic in the iSeries Information Center.
Some software problems can be temporarily solved by changing the configuration parameter, even if the
original value was correct. Report this problem to your service representative if you use this temporary
change.

UJE40

For use by authorized service providers.
The problem may be at the remote site or on the network media.
Perform the following:
1. Ask the remote site operator to verify the following:
v The remote equipment is powered on and ready.
v The configuration values are correct.
v The local area network cables are securely connected and are not damaged.
2. If the problem continues, run all available diagnostic tests on the remote equipment and perform the
repair action specified.
This ends the procedure.