Sdiop-Pip32; Sdiop-Pip33 - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

v The removable cache card from the new storage I/O adapter (this applies to only some 2780 I/O
adapters). See Type 2748, 2757, 2763, 2778, 2780, 2782, 5703 - Cache directory card.
v If the I/O adapter is attached to an auxiliary cache I/O adapter, ensure that the SCSI cable on the
last port of the new replacement storage I/O adapter is connected to the auxiliary cache I/O adapter.
For a list of auxiliary cache I/O adapters, see the Type, model, and part number list.
This ends the procedure.
SDIOP-PIP32: For use by authorized service providers.
You were sent to this procedure from URC 9011.
Attention: There is data in the cache of this I/O card, that belongs to devices other than those that are
attached. Customer data may be lost.
1. If the system has logical partitions, perform this procedure from the logical partition that reported the
problem. To determine if the system has logical partitions, go to Determine if the system has logical
partitions, before continuing with this procedure.
2. Did you just exchange the storage I/O adapter as a result of a failure?
v No: Continue with the next step.
v Yes: Reclaim the cache storage (see Reclaim IOP cache storage).
Does the IPL complete successfully?
– No: Go to "Starting point for all problems" on page 2.
This ends the procedure.
– Yes: This ends the procedure.
3. Have the I/O cards been moved or reconfigured recently?
v No: Ask your next level of support for assistance.
This ends the procedure.
v Yes: Perform the following:
a. Power off the system (see Power on/off the system and logical partitions).
b. Restore all I/O cards to their original position.
c. Select the IPL type and mode that are used by the customer (see iSeries Service Functions
d. Power on the system.
).
Does the IPL complete successfully?
– No: Ask your next level of support for assistance.
This ends the procedure.
– Yes: This ends the procedure.
SDIOP-PIP33: For use by authorized service providers.
You were sent to this procedure from URC 9001.
The I/O processor card detected a device configuration error. The configuration sectors on the device may
be incompatible with the current I/O processor card.
1. If the system has logical partitions, perform this procedure from the logical partition that reported the
problem. To determine if the system has logical partitions, go to Determine if the system has logical
partitions before continuing with this procedure.
2. Has the I/O adapter been replaced with a different type of I/O adapter, or have the devices been
moved from a different type of I/O adapter to this one?
v No: Contact your next level of support.
This ends the procedure.
210
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation