Loosen setscrew ❺ in the spreader stopper and
adjust the position of spreader stopper ❻. Then fix
the spreader in place. (Make the same adjustment
for both left/right spreaders.)
● Timing to open/close the spreaders
To
aligned
In the case of the outer needle, the correct timing
is such that the left spreader completely closes at
the moment when the end face (side face) of the
needle is aligned with the top end of the left looper
Needle
while the needle bar comes down and the left looper
travels backward.
When the inner needle rests at its lower dead point,
the right spreader is in the closed state.
Loosen setscrew ❽ of spreader driving shaft guide
❼. Adjust the timing by moving the guide up and
down. Then, fix the spreader driving shaft guide by
tightening the setscrew.
− 86 −
Make sure of the width or the timing when
the stitch bite width is changed or after
performing the looper timing adjustment.
Take care not to damage or deform needle
thread trimming spring ❾.