No.
731
Faulty main shaft hole sensor/position sensor
In the case the hole sensor/position sensor of the sewing machine is faulty
733
Reverse rotation of main shaft motor
In the case the main shaft motor rotates in the reverse direction of rotation
750
Emergency stop switch
In the case the ON signal of the emergency stop switch is detected
811
Overvoltage
In the case the input supply voltage is equal to or more than the specified
value
813
Low voltage
In the case the input supply voltage is equal to or less than the specified
value
820
24 VDC power supply off
In the case the 24 VDC supply voltage is equal to or less than the specified
value
901
Faulty main shaft motor IPM
In the case the SDC PWB IPM is faulty
903
Faulty 85 VDC supply voltage
In the case the 85 VDC supply voltage falls out of the specified range
904
Faulty 24 VDC supply voltage
In the case the 24 VDC supply voltage falls out of the specified range
905
Faulty SDC PWB temperature
Re-turn ON the power supply after a certain period of time
907
Lateral-direction motor origin sensor error
In the case the lateral-direction origin sensor does not change at the time
of origin retrieval
908
Longitudinal-direction motor origin sensor error
In the case the longitudinal-direction origin sensor does not change at the
time of origin retrieval
914
Fault feed error
In the case synchronism between the sewing machine and the feed is not
achieved
915
Communication error between the operation panel and the MAIN PWB
Communication between the operation panel and the MAIN PWB cannot
be carried out
916
Communication error between the MAIN PWB and SDC PWB
Communication between the MAIN PWB and SDC PWB cannot be carried
out
918
Faulty temperature of MAIN PWB 
Re-turn ON the power supply after a certain period of time
926
Lateral-direction motor out-of-position error 
In the case the lateral-direction motor is out of position
Longitudinal-direction motor out-of-position error  
927
In the case the longitudinal direction motor is out of position.
931
Lateral-direction motor overload error 
In the case the lateral-direction motor is overloaded
932
Longitudinal-direction motor overload error 
In the case the longitudinal-direction motor is overloaded
946
Machine head memory writing error 
In the case data cannot be written on the memory of INT PWB
997
Rotating motor overload error 
In the case the rotating motor is overloaded
998
Rotating motor out-of-position error 
In the case the rotating motor is out of position
999
Rotating motor origin sensor error 
In the case the rotation origin sensor does not change at the time of origin
retrieval
Description
– 105 –
How to reset
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.
Turn OFF the power.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meb-3810njMeb-3810nc

Table of Contents