Building a Stack

Displaying information on stack connections

To check the software version installed on each stack unit, enter the show version command. The software versions should
match. If they do not match, refer to "Stack mismatches."
Copyright (c) Ruckus Networks, Inc. All rights reserved.
UNIT 1: compiled on Dec 20 2018 at 10:49:04 labeled as SWR08090dev
(30070372 bytes) from Primary SWR08090dev.bin
SW: Version 08.0.90devT203
Compressed Boot-Monitor Image size = 1835008, Version:10.1.12T205 (swz10112)
Compiled on Thu Jun
UNIT 2: compiled on Dec 21 2018 at 16:38:54 labeled as SWR08090dev
(30066821 bytes) from Primary SWR08090dev.bin
SW: Version 08.0.90devT203
Compressed Boot-Monitor Image size = 1835008, Version:10.1.06T205 (swz10106b002)
UNIT 3: compiled on Dec 20 2018 at 10:49:04 labeled as SWR08090dev
(30070372 bytes) from Primary SWR08090dev.bin
SW: Version 08.0.90devT203
Compressed Boot-Monitor Image size = 1835008, Version:10.1.06T205 (swz10106b002)
NOTE
For field descriptions of the show stack , show stack detail , and show version commands, refer to "Displaying stack
information."
Displaying information on stack connections
You can check the data connections between stack units with the show stack connection command.
When the show stack connection command output includes the message *** error: one-way, this may indicate a stack port
to non-stack-port connection. When this occurs, the side of the connection that is incorrectly configured as a stack port must be
converted to a data port.
86
7 04:42:06 2018
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01