Icx 7250 Stack Configuration Overview - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

Stacking by Device

ICX 7250 stack configuration overview

The following example converts stacking port 1/3/3 to a data port.
ICX7150-24 Router# configure terminal
ICX7150-24 Router(config)# stack unit 1
ICX7150-24 Router(config-unit-1)# no stack-port 1/3/3
stack-port 1/3/3 is removed.
ICX7150-24 Router(config-unit-1)# show stack
T=41m15.7: alone: standalone, D: dynamic cfg, S: static
ID
Type
1
S ICX7150-24
2
S ICX7150-48P
standby
active
+---+
3/3| 2 |3/1==3/1| 1 |
+---+
Will assign standby in 58 sec due to all ready
Standby u2 - protocols ready, can failover
Current stack management MAC is 00e0.5200.0100
ICX 7250 stack configuration overview
The following table provides an overview of ICX 7250 stacking capabilities.
TABLE 21 ICX 7250 stacking capability
Stacking capability
Topologies supported
Maximum stack size
Maximum stacking distance
Stacking ports
Valid-stack-port sets
102
Role
Mac Address
active
00e0.5200.0100 128 local
standby 748e.f882.e418
+---+
+---+
ICX 7250
Ring and linear
12 units
10 Kilometers
Four 10-Gbps stacking ports (from eight
available ports) on fixed module on front
panel
Factory set (x/2/1, x/2/3, 2) or (x/2/5, x/2/7, 2)
Pri State
Comment
Ready
0 remote
Ready
NOTE
The third number in each set is
the maximum number of ports in
a stacking trunk.
Additional information
Refer to
ICX 7250 stacking topologies
103.
Stacking and SPX configurations. Any
combination of ICX 7250 devices may be
stacked. When a stand-alone ICX 7250 is
configured as a PE unit attached to a control
bridge in an 802.1br SPX configuration,
scaling is increased. Refer to the Ruckus
FastIron Campus Fabric Configuration Guide for
more information.
Refer to
FastIron stacking distances and
optics by device
on page 50 for more
information.
Module 2 on the front panel contains four
stacking ports and four uplink ports, which
can be used as alternative ports for stacking.
Refer to
ICX 7250 stacking topologies
103 for module and port locations.
Refer to the definition of valid-stack-port set
in
Stacking terminology
on page 19 and
stack-port sets
on page 23 for more
information.
Refer to
ICX 7250 stacking topologies
103 for port locations.
Ruckus FastIron Stacking Configuration Guide, 08.0.90