Moving A Unit To Another Stack; Removing An Active Controller From A Powered Stack; Reloading A Stack Unit - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

!!! Temperature is over warning level on stack unit 1 !!!
Detect stack unit 3 has different startup config flash, will synchronize it
Detect stack unit 3 has different ssh rsahost key, will synchronize it
T:3h49m7.9: Done hot swap: active controller u1 sets u3 to Ready.
T=3h49m7.9: Synchronize startup config to u3
Flash Memory Write (8192 bytes per dot)
.
Write startup-config done.
T=3h49m31.3: Election, was active, no change, ID=1, pri=128, 3U(1-3), A=u1, nbr#=1 1, reason: u2: port-up, ,
Stack unit 3 Power supply 1 is up
Stack unit 3 Power supply 2 is down
T=3h49m35.5: Election, was active, no change, ID=1, pri=128, 3U(1-3), A=u1, nbr#=2 2, reason: u3: port-up, ,
SSH RSA Host Key erase request sent to specified stack member(s)...
T=3h49m16.7: Synchronize ssh rsa host key to u3
ICX7750-26Q Router#
When the interactive-setup process is complete, output for the show stack command confirms that the configuration is the
same. The provisional configuration has been applied to the two replacement units, 2 and 3, and the state has changed to
"remote" for both units.
ICX7750-26Q Router# show stack
T=3h49m27.4: alone: standalone, D: dynamic cfg, S: static
ID
Type
1
S ICX7750-20QXG active
2
S ICX7750-48XGF member
3
S ICX7750-20QXG member
active
+---+
+---+
=2/1| 1 |2/4==2/1| 3 |2/4==2/4| 2 |2/1=
|
+---+
+---+
|
|-------------------------------------|
There is no standby. Will assign a standby in 47 sec
Current stack management MAC is cc4e.2438.7280

Moving a unit to another stack

Moving a member from one stack to another stack can cause non-sequential ID assignment. The active controller will honor the
original ID of the newly added unit if the ID is not already in use. The active controller assigns a new ID if the original ID is already
in use. You can user the stack interactive-setup command to change the ID of the new unit. Refer to
with stack interactive-setup

Removing an active controller from a powered stack

To remove an active controller from a powered stack, disconnect the active controller. The standby controller waits for 30
seconds and then assumes the role of active controller. If hitless failover is enabled on the stack, the standby controller takes
over immediately. A single active controller device functions as a standalone unit even if it is still stacking-enabled. You do not
have to issue a stack unconfigure me command for an active controller.

Reloading a stack unit

Use the reload command to reload one or more stack units, for example, when necessary to repair a malfunctioning unit. Stack
units can be reloaded only if they are not the active controller.
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
Role
Mac Address
cc4e.2438.7280 128 local
609c.9f7f.9400
748e.f8f9.6300
+---+
+---+
|
|
on page 75 for more information.
Pri State
Comment
Ready
0 remote
Ready
0 remote
Ready
Stack Management

Reloading a stack unit

Changing stack unit IDs
215