Fastiron stacking configuration
Table of Contents

Advertisement

Changes to Stacking in FastIron Release 08.0.90
Support for two-unit stack linear-topology trunks
ICX7250-48P Router#
The other units reloads, becomes a member, and joins the stack.
T=6m9.2: Election, was alone --> active, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 0, reason: u2: enable, ,
T:6m11.3: Done hot swap: active controller u1 sets u2 to Ready.
T=6m12.0: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 0, reason: u1: stk-po-
chg, ,
Config changed due to add/del units. Do write mem if you want to keep it
T=7m12.7: Assigned unit 2 to be standby
ICX7250-48P Router# write memory
There is no startup config file, unable to save legacy config
Automatic copy to member units:
Flash Memory Write (8192 bytes per dot)
.
Copy Done.
ICX7250-48P Router#
================Unit 2 Log=================================
ICX7250-48P Router#Unit 1 receives stack interactive-setup from U1, mac=609c.9f99.3f80
ID=2 D0=2/1 to 2/4, , will reload from Primary in 20 sec
Unmounting the External USB
We are in system reset
#### Bootup printout is snipped
The system : started=warm start
My stack unit ID = 2, bootup role = member
[MEMBER]local-2@ICX7250-48P Router>
Creating certificate, please wait...
SSL Client Certificate is successfully created
[MEMBER]local-2@ICX7250-48P Router>
T=48.5: Election, was member, no change, ID=2, pri=0, 2U(1-2), A=u1, nbr#=1 0, reason: u1: stk-po-chg, ,
Unit 2 becomes ready
Connecting to active controller 1 console...(Press Ctrl Shift -
T=51.5: Election, was member, no change, ID=2, pri=0, 2U(1-2), A=u1, nbr#=1 0, reason: u1: stk-po-chg, ,
ICX7250-48P Router>
UNIT2:T=1m52.0: Unit 2 is assigned standby by active u1.
T=1m54.2: Standby u2 start parsing running config from active controller u1
T=1m54.5: Standby u2 finished parsing running config from active controller u1.
T:1m56.8: Done hot swap: standby controller u2 sets u1 to Ready.
Download request from active unit 1 mac = 609c.9f99.3f80
UNIT2:T=2m54.6: U2 received startup config flash sync.
Done.
Creating a two-unit linear-topology stack using stack zero-touch
provisioning
Stack zero-touch provisioning elects to form a linear-topology trunk only when the active controller has a linear-topology trunk
configuration for itself. If the active controller does not have a linear-topology trunk configuration, stack zero-touch provisioning
forms a ring.
The following procedure uses an ICX 7250 stack as an example. A two-unit ICX 7250 stack has two potential linear-topology
trunks, (x/2/1 to x/2/4) and (x/2/5 to x/2/8). The system configures a four-port trunk and removes the other direction.
42
2
reloaded=by "reload"
x to exit)
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01