Troubleshooting Stack Interactive-Setup - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

ICX Stack Troubleshooting

Troubleshooting stack interactive-setup

7.
Check to be sure you do not have any stacking to non-stacking connections. All platforms use proprietary link
negotiation to detect whether a stacking port's neighbors are also stacking ports. The platforms then convert both sides
from IEEE mode (used in data ports) to HiGig mode (used in internal ports). Under stable conditions, both ends of a
stacking link are converted to HiGig mode. If a stacking port is UP but in IEEE mode, its neighbor is not a stacking port.
Enter the show stack stack-ports command to check if any stacking port is UP but in IEEE mode. The following example
shows that U3 ports 3/2/1 to 3/2/3 are UP and in IEEE mode as indicated by the up* mark.
ICX7750-26Q Router(config-unit-3)# show stack stack-ports
+---+
2/1| 3 |2/4==2/4| 1 |2/1==2/1| 2 |
+---+
U#
Stack-port1
1
up 1/2/1 to 1/2/3
up ports: 1/2/1, 1/2/2, 1/2/3
up ports: 1/2/4, 1/2/5, 1/2/6
2
up 2/2/1 to 2/2/3
up ports: 2/2/1, 2/2/2, 2/2/3
up ports: 1/2/4, 1/2/5, 1/2/6
3
up* 3/2/1 to 3/2/3
up ports: 3/2/1, 3/2/2, 3/2/3
up ports: 3/2/4, 3/2/5, 3/2/6
Note: *: Port is up in IEEE mode, not in HiGig mode.
8.
If you run out of flash memory while performing a write memory, your stack devices may contain very large startup-
config.v4 or startup-config.old files, which are preserved for recovery purposes. Enter the show dir command at the
privileged EXEC level to see all flash files. If you identify these old files and they are not needed, you can delete them by
entering the flash delete command at the privileged EXEC level as shown in the following example.
ICX7450-48F Router# show dir
Type
----------------------
F
27615428 primary
F
27851652 secondary
F
F
F
F
F
F
F
55551779 bytes 9 File(s) in FI root
1766779193 bytes free in FI root
1766779193 bytes free in /
ICX7450-48F Router# flash delete
ASCII string
ICX7450-48F Router# flash delete startup-config.old

Troubleshooting stack interactive-setup

Stack interactive-setup can be used to form linear and ring stack topologies. For information about the procedure, refer to
Scenario 1 - Using stack interactive-setup to create a stack
240
standby
active
+---+
+---+
+---+
+---+
Size
Name
21 sil_logs
2361 startup-config.backup
2361 startup-config.old
2442 startup-config.txt
256 secondary.sig
256 bootrom.sig
77002 debug.boot
flash file name to delete
Stack-port2
up 1/2/4 to 1/2/6
none
up 3/2/4 to 3/2/6
on page 57.
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01