For examples of hitless stacking switchover operation, refer to

Executing a hitless stacking switchover

The following must be in effect before a hitless switchover (to the standby controller) is allowed:
Hitless stacking is enabled.
The stack has a standby controller.
The standby controller has learned the protocols.
The standby controller has the same priority as the active controller.
More than 120 seconds have passed since the previous switchover or failover.
You can use the show stack command to check these criteria.
To perform a switchover, enter the following command.
device# stack switch-over
Standby unit 8 will become active controller, and unit 1 will become standby
Are you sure? (enter 'y' or 'n'): y
Unit 1 is no longer the active controller

Hitless stacking switchover examples

The following examples illustrate hitless stacking failover and switchover operation during a CLI-driven switchover or priority
change.
The following figure illustrates a hitless stacking switchover triggered by the stack switch-over command.
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
Hitless stacking switchover examples
Hitless Stacking
Hitless stacking switchover
on page 183.