ICX7250-48P Router# show running-config
Current configuration:
!
ver 08.0.90
!
stack unit 1
module 1 icx7250-48p-poe-port-management-module
module 2 icx7250-sfp-plus-8port-80g-module
priority 128
stack-trunk 1/2/1 to 1/2/4
stack unit 2
module 1 icx7250-48p-poe-port-management-module
module 2 icx7250-sfp-plus-8port-80g-module
stack-trunk 2/2/1 to 2/2/4
stack enable
stack zero-touch-enable
stack mac 609c.9f99.3f80
!
!
hitless-failover enable
!
!
end
ICX7250-48P Router# show stack
T=41m18.8: alone: standalone, D: dynamic cfg, S: static
ID
Type
1
S ICX7250-48P
2
D ICX7250-48P
standby
active
+---+
| 2 |2/1==2/1| 1 |
+---+
Standby u2 - protocols ready, can failover
Role history: N: standalone, A: active, S: standby, M: member
U1: N->A
Current stack management MAC is 609c.9f99.3f80
ICX7250-48P Router# write memory

Changing a live two-unit stack to a linear-topology trunk

The ICX system performs numerous checks to block commands that could break a live stack. However, the checks have
limitations and may not catch all potential breaks. Therefore, you should verify the physical connections on the stack before
using the multi-stack-port or multi-stack-trunk command.
You can use the show stack connection command to check the physical connections of stacking ports (data port connections
are not shown).
In a live system, you can configure the desired trunk on both units simultaneously using the multi-stack-trunk command.
In the following procedure, an ICX 7250 two-unit linear-topology stack is created as an example. Each ICX 7250 device has two
potential linear-topology trunks, (x/2/1 to x/2/4) and (x/2/5 to x/2/8). When you configure either trunk, the system creates the
specified trunk on each unit and removes the other stacking direction.
1.
Enter global configuration mode on the active controller.
ICX 7250# configure terminal
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
Role
Mac Address
active
609c.9f99.3f80 128 local
standby 609c.9f99.1988
+---+
+---+
Pri State
Comment
Ready
0 remote
Ready
Changes to Stacking in FastIron Release 08.0.90
Support for two-unit stack linear-topology trunks