Scenario 3 - Manually configuring a three member stack in a ring
topology
If you are connecting units that have been individually configured for stacking and want unit IDs to be assigned based on
physical sequence, you may want to configure the stack manually.
Complete the following steps to configure a three-member stack in a ring topology using the manual configuration process. In
this example, device 1 is the active controller, and device 2 is the standby controller. Unit 3 boots up as a member, based on the
configured priorities for units 1 and 2.
1.
Power on the devices. Do not connect the stacking cables at this point.
2.
Assign a priority of 255 to unit 1 and a priority of 240 to unit 2 using the priority command. You do not have to assign a
priority to the third unit.
3.
Enter the stack enable command on each device.
In this example, device 1 is the active controller, and device 2 is the standby controller.
Unit 1
device# configure terminal
device(config)# stack unit 1
device(config-unit-1)# priority
device(config-unit-1)# stack
Enable stacking. This unit actively participates in stacking
device(config-unit-1)# write memory
Write startup-config done.
Flash Memory Write (8192 bytes per dot) .Flash to Flash Done.
device(config-unit-1)# end
Unit 2
device# configure terminal
device(config)# stack suggested-id 2
device(config)# stack unit 1
device(config-unit-1)# priority
device(config-unit-1)# stack enable
Enable stacking. This unit actively participates in stacking
device(config-unit-1)# write memory
Write startup-config done.
Flash Memory Write (8192 bytes per dot) .Flash to Flash Done.
device(config-unit-1)# end
Unit 3
device# configure terminal
device(config)# stack suggested-id 3
device(config)# stack enable
Enable stacking. This unit actively participates in stacking
Write startup-config done.
Flash Memory Write (8192 bytes per dot) .Flash to Flash Done.
device(config-unit-1)# end