Mib Support For Icx Stack Configurations - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

3.
Enter the show stack zero-touch log command in Privileged EXEC mode to display the system log for the stack zero-
touch and interactive-setup processes. SPX zero-touch and interactive-setup information is also included in the log.
ICX7750-48F Router# show stack zero-touch log
Note: The logs are shared by Spx and Stack ZTP/interactive-setup.
8m38.7989 init_zero_touch(1) u_off=0, init_T=5178 , 1U 0P A0S0 I1N 5%
9m41.5928 ZTP mode=1, 6 .5min T, cb_state = 0, diff = 580 s, diff=580 > 90 sec, trigger probe, , 1U
0P A0S0 I1N 3%
9m41.8670 Send ZTP probes: ports: 1/2/1 to 1/2/6 1/3/1 to 1/3/6 PEs: , 1U 0P A0S0 I1N
9m53.5723 ZTP 100ms: tk=29, st=1, cb_tk=29 mx_tk=30, pb, wa=2, , 1U 0P A0S0 I1N
9m53.9720 ZTP 100ms: tk=30, st=1, cb_tk=30 mx_tk=30, ->GET_R, wa=20,, 1U 0P A0S0 I1N
10m5.5770 ZTP 100ms: tk=50, st=2, cb_tk=19 m_tk=20, pb, wa=5, , 1U 0P A0S0 I1N
10m5.5779 cb_r_probe. ztp_mode=1, rec#=2, load=162, inv [0] cc4e.2439.3700,
2439.1a00 <= cc4e.2439.3700, cannot overwrite, 1U 0P A0S0 I1N
10m5.5781 cb_r_probe. ztp_mode=1, rec#=2, load=162, inv [0] cc4e.2439.1a00,
A0S0 I1N
10m5.5782 cb_r_probe_2nd. rec#=2, load=192, tot C=1, ztp_m=1 , 1U 0P A0S0 I1N
10m5.9765 stk_ztp_send_id_port_acl C0 mac#=4:
10m5.9766 C0, dr=0 rin=1 me=1/4
#1 cc4e.2439.1a00 U3, D0: 2/1 to 2/3, D1: 2/4 mac: me=1u cb=0: mis-m=0 , 1U 0P A0S0 I1N
10m5.9767 C0, dr=0 rin=1 me=2/4
#2 cc4e.2439.3700 U2, D0: 2/1, D1: 2/4 mac: me=2u cb=3: mis-m=0 , 1U 0P A0S0 I1N
10m5.9770 Send C0 len=880, 2U: 1a00 3700 res=1 Z_CMD: CB u1 cc4e.246d.9e00, cmd=0, ack=0 #rec=2, d=0
0 0 0, H=28B 875B, ztp_m=10: m=8ef8 S=28(63843) C=110, *** Err: sta28 + size 63843=63871 > 875, 1U
0P A0S0 I1N
10m5.9771 chain 0:
#1 cc4e.2439.1a00 U3, D0: 2/1 to 2/3, D1: 2/4
#2 cc4e.2439.3700 U2, D0: 2/1, D1: 2/4
, 1U 0P A0S0 I1N
10m5.9771 Send cleanup 20 sec, rel=1, to (chain# res): Send KA 20s rel=1, C0 1, , 1U 0P A0S0 I1N
10m5.9771
10m5.9772 ZTP 100ms: tk=51, st=2, cb_tk=20 m_tk=20, f 1 C, unsta=0, , 1U 0P A0S0 I1N
10m17.2617 Stk ZTP clean T: mode=0 SS running=0, has SS clean-T, reconfig=2, ZTP EN,
C0, deinit_rel: , 1U 0P A0S0 I1N 99%
12m26.8255 ZTP chg_cb(old=0, new=1): I new-A, ZTP m=1 en, init, , 1U 0P A1S0 I1A 7%
12m44.3562 topo chg: during ztp reload, abort.
, 2U 0P A1S0 I1A

MIB support for ICX stack configurations

All statistics about packets received and sent, RMON, jumbo frames (greater than 1518 bytes), runts, giants, and other instances
are gathered through the stack interfaces and are accessible through SNMP. MIB support for ICX stack configurations is the same
as for a standard interface. Information includes types of modules, including optics modules.
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
total=2, send clean, set 20s T, , 1U 0P A0S0 I1N

MIB support for ICX stack configurations

636e 1a63 376b 636e , 1U 0P A0S0 I1N
Stack Management
rec#=2, exist mac=cc4e.
use old 0,
, 1U 0P
reset: free: X
235