Changes to Stacking in FastIron Release 08.0.90
Support for two-unit stack linear-topology trunks
2.
Enter stack unit configuration sub-mode on the active controller.
ICX 7250(config)# stack unit 1
3.
Configure the desired trunk on each unit.
Based on existing connections, specify one of the available trunk combinations.
For example, in an ICX 7250 two-unit stack, based on connections, specify one of the following choices for each side of
the trunk when entering the multi-stack-trunk command:
x/2/1 to x/2/4
x/2/5 to x/2/8
ICX 7250(config-unit-1)# multi-stack-trunk 1/2/1 to 1/2/4 and 2/2/1 to 2/2/4
The system changes any existing stack-port or stack-trunk configuration to a four-port linear-topology trunk.
In the example, both units form a bidirectional linear-topology stacking trunk on ports x/2/1 through x/2/4.
4.
Enter the write memory command to save the configuration.
ICX 7250(config-unit-1)# exit
ICX 7250(config)# write memory
The following example creates a linear-topology trunk and includes system responses.
ICX7250-48P Router# configure terminal
ICX7250-48P Router(config)# stack unit 1
ICX7250-48P Router(config-unit-1)# multi-stack-trunk 1/2/1 1/2/2 1/2/3 1/2/4 and 2/2/1 2/2/2 2/2/3 2/2/4
stack-trunk 1/2/1 to 1/2/4 replaces stack-trunk 1/2/1 to 1/2/2 and stack-trunk 1/2/3 to 1/2/4
stack-trunk 2/2/1 to 2/2/4 replaces stack-trunk 2/2/1 to 2/2/2 and stack-trunk 2/2/3 to 2/2/4
ICX7250-48P Router(config-unit-1)# exit
ICX7250-48P Router(config)# show running-config
Current configuration:
!
ver 08.0.90
!
stack unit 1
module 1 icx7250-48p-poe-port-management-module
module 2 icx7250-sfp-plus-8port-80g-module
priority 128
stack-trunk 1/2/1 to 1/2/4
stack unit 2
module 1 icx7250-48p-poe-port-management-module
module 2 icx7250-sfp-plus-8port-80g-module
stack-trunk 2/2/1 to 2/2/4
stack enable
stack mac 609c.9f99.3f80
!
!
ICX7250-48P Router(config)# write memory

Changing a live linear-topology trunk to a ring

The ICX system performs numerous checks to block commands that could break a live stack. However, the checks have
limitations and may not catch all potential breaks. Therefore, you should verify the physical connections on the stack before
using the multi-stack-port or multi-stack-trunk command.
You can use the show stack connection command to check the physical connections of stacking ports (data port connections
are not shown).
46
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01