Comparison Of Configuration Changes That Use Non-Factory Valid-Stack-Port Sets; Comparison Of Common Configuration Procedures Using Factory-Set Default Stacking Ports - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

Changes to Stacking in FastIron Release 08.0.90
Changes to stack-port and stack-trunk configuration
Comparison of configuration changes that use non-factory valid-
stack-port sets
The following table provides a side-by-side comparison of new and old configuration command behaviors for stack
configurations that use stack-ports other than the factory-set default ports. In the table, an ICX 7750 stack serves as the example,
and configuration changes use stack-ports other than the factory-set combination (ports 1/2/1 and 1/2/4). The new behavior
does not require you to use the default-ports command.
TABLE 4 Comparison of commands that use valid-stack-ports other than the factory-set default stacking ports
Objective
1 port
2 ports
1 trunk
1 port and 1 trunk
2 trunks
Comparison of common configuration procedures using factory-set
default stacking ports
The following series of tables provide side-by-side comparisons of new and old configuration behaviors required for standard
stack configuration procedures when factory-set default stacking ports are used. The examples reference ICX 7750 stack
configuration, for which factory-set default stacking ports are 1/2/1 and 1/2/4.
The old behavior sometimes required multiple commands to add or delete one stack-port or stack-trunk and sometimes needed
only one command to add or delete two stack-ports or stack-trunks. In contrast, the new behavior always adds or deletes a
stack-port or stack-trunk with one command.
TABLE 5 Removing a stacking port
Initial configuration
Remove stack-port 1/2/1
Final configuration
26
New behavior
stack-port 1/3/1
stack-port 1/2/1
stack-port 1/3/1
stack-trunk 1/3/1 to 1/3/3
stack-port 1/2/1
stack-trunk 1/3/1 to 1/3/3
stack-trunk 1/2/1 to 1/2/3
stack-trunk 1/3/1 to 1/3/3
New behavior
stack-port 1/2/1
stack-port 1/2/4
no stack-port 1/2/1
stack-port 1/2/4
Old behavior
default-ports 1/2/1 1/3/1
stack-port 1/3/1
default-ports 1/2/1 1/3/1
stack-port 1/2/1 1/3/1
default-ports 1/2/1 1/3/1
stack-port 1/3/1
stack-trunk 1/3/1 to 1/3/3
default-ports 1/2/1 1/3/1
stack-port 1/2/1 1/3/1
stack-trunk 1/3/1 to 1/3/3
default-ports 1/2/1 1/3/1
stack-port 1/2/1 1/3/1
stack-trunk 1/2/1 to 1/2/3
stack-trunk 1/3/1 to 1/3/3
Old behavior
stack-port 1/2/1 1/2/4
no stack-port 1/2/1
or
stack-port 1/2/4
stack-port 1/2/4
Ruckus FastIron Stacking Configuration Guide, 08.0.90