Syslog Messages For Hitless Stacking Failover And Switchover - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

STACKING_POE_SCTRL messages sent: 0,
STACKING_POE_STATUS messages sent: 0,
global_ctrl_dest: 0
individual_ctrl_dest: 0
status_dest: 2
Syslog messages for hitless stacking failover and
switchover
Syslog messages are generated for the following events:
Switchover
Failover
Standby controller assignment
The following table lists the supported syslog messages for hitless stacking failover and switchover.
TABLE 27 Supported syslog messages for hitless stacking faiilover and switchover
Message level
Informational
Informational
Informational
To view the system log or the traps logged on an SNMP trap receiver, enter the show log command at any level of the CLI. The
following sample output shows what the log may look like after a switchover or assignment of the standby controller.
device# show log
Syslog logging: enabled (0 messages dropped, 1 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warningDynamic Log Buffer (50 lines):
0d00h05m34s:I:System: Interface ethernet mgmt1, state up
0d00h05m33s:I:Stack: Stack unit 8 has been assigned as STANDBY unit of the stack system
0d00h05m33s:I:Stack: Stack is operational due to SWITCH-OVER
0d00h05m32s:I:Stack: Stack unit 1 has been elected as ACTIVE unit of the stack system
0d00h05m29s:W:System:Stack unit 2 Fan speed changed automatically to 2
0d00h05m25s:W:System:Stack unit 5 Fan speed changed automatically to 2
0d00h05m00s:I:System: Interface ethernet mgmt1, state down
0d00h05m00s:I:Security: Telnet server enabled by
The following sample output shows what the log may look like after a failover of the active controller.
device# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 12 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Dynamic Log Buffer (50 lines):
0d00h04m41s:I:Stack: Stack unit 3 has been assigned as STANDBY unit of the stack system
0d00h04m12s:I:System: Interface ethernet mgmt1, state up
0d00h04m10s:I:System: Interface ethernet mgmt1, state down
0d00h04m10s:I:System: Interface ethernet mgmt1, state up
0d00h04m09s:I:STP: VLAN 1 Bridge is RootBridge: 800000e052010000 (MgmtPriChg)
0d00h04m09s:I:System: Management MAC address changed to 0000.0001.0000
0d00h04m09s:I:Stack: Stack is operational due to FAIL-OVER
0d00h04m08s:I:Stack: Stack unit 1 has been elected as ACTIVE unit of the stack system
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
received: 0
received: 0
Message
Stack: Stack unit unit_number has been
assigned as STANDBY unit of the stack system
Stack: Stack is operational due to SWITCH-
OVER
Stack: Stack is operational due to FAIL-OVER
from
session

Syslog messages for hitless stacking failover and switchover

Explanation
Indicates that the unit has been assigned as
the standby controller.
Indicates that a switchover has occurred.
Indicates that a failover has occurred.
Hitless Stacking