Stack Management

Stack software images

Changing the priority of a stack unit

To change the priority value for a stack unit, enter the priority command at the stack unit configuration level. The priority can be
a value from 0 through 255, where 255 is the highest priority.
device# configure terminal
device(config)# stack unit 1
device(config-unit-1)# priority 128

Stack software images

Consider the notes in this section when upgrading or downgrading a stack.
Refer to the release notes and to the Ruckus FastIron Software Upgrade Guide for instructions about upgrading the software.

Confirming stack software versions

All units in a stack must be running the same software image. To confirm this, check the software version on all devices that you
want to add to a stack. Upgrade any units that are running older versions of the software before you build the stack.
To check the software version for each stack member, perform the following steps.
1.
Use Telnet or SSH or connect to any of the console ports in the stack.
2.
Enter the show version command. Output similar to the following is displayed.
ICX7750-26Q Router# show version
Copyright (c) 2017 Ruckus Wireless, Inc. All rights reserved.
UNIT 1: compiled on Jul 31 2015 at 18:37:27 labeled as SWR08040b1
(20197181 bytes) from Primary SWR08040b1.bin
SW: Version 08.0.40b1T203
UNIT 2: compiled on Jul 31 2015 at 18:37:27 labeled as SWR08040b1
(20197181 bytes) from Primary SWR08040b1.bin
SW: Version 08.0.40b1T203
UNIT 3: compiled on Jul 31 2015 at 18:37:27 labeled as SWR08040b1
(20197181 bytes) from Primary SWR08040b1.bin
SW: Version 08.0.40b1T203
Compressed Boot-Monitor Image size = 1835008, Version:10.1.01T205 (swz10101)
Compiled on Fri Jun 27 22:01:35 2014
NOTE
If any unit in the stack is running an incorrect version of the software, it will appear as non-operational. You
must install the correct software version on that unit for it to operate properly in the stack.

Stack mismatches

When a stack mismatch occurs, the active controller can put any stack member into a non-operational state, which disables all of
the ports except the stacking ports. Stack mismatches can occur for a variety of reasons.
NOTE
After a stack mismatch, the active controller can still download an image to the non-operational unit.
202
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01