Hitless Stacking
Displaying information about hitless stacking
+---+
-2/1| 1 |2/4--2/1| 3 |2/4--2/1| 2 |2/4-
|
+---+
+---+
|
|-------------------------------------|
Standby u2 - protocols ready, can failover
Current stack management MAC is 748e.f8f9.6300
Displaying information about stack failover
Use the show stack failover command to view information about rapid failover.The show stack failover command provides
information on the current standby controller and its status as shown in the following example.
device# show stack failover
Current standby is unit 2. state=ready
Standby u2 - protocols ready, can failover
Displaying hitless stacking status
The show stack command indicates whether hitless stacking is enabled. The following example shows that hitless stacking is
disabled.
ICX7750-26Q Router(config-unit-1)# show stack
T=17m47.9: alone: standalone, D: dynamic cfg, S: static
ID
Type
1
S ICX7750-26QXG active
2
D ICX7750-26QXG member
3
D ICX7750-26QXG standby cc4e.2438.7500
active
standby
+---+
=2/1| 1 |2/4==2/1| 3 |2/4--2/1| 2 |2/4=
|
+---+
+---+
|
|-------------------------------------|
Standby u3 - No hitless failover. Reason: hitless-failover not configured
Displaying pending device roles
When hitless stacking is disabled, a priority change triggers an election, but the newly-elected winner does not assume its role
until the entire stack is reloaded or hitless stacking is enabled. You can use the show stack command to view pending device
roles. The "Role" column displays the current role for each unit. The "Comment" column displays the role that will take effect after
a reload or when hitless stacking is enabled.
ICX7750-26Q Router(config-unit-1)# show stack
T=17m47.9: alone: standalone, D: dynamic cfg, S: static
ID
Type
1
S ICX7750-26QXG active
2
D ICX7750-26QXG member
3
D ICX7750-26QXG standby cc4e.2438.7500 200 remote
Displaying information about link synchronization status
Use the show stack link-sync status command to view the status of the link synchronization.
ICX7750-26Q Router# show stack link-sync status
STACKING_LINK_GLOBAL_CTRL messages sent: 0,
STACKING_LINK_INDIVIDUAL_CTRL messages sent: 0,
STACKING_LINK_STATUS messages sent: 235,
188
+---+
+---+
+---+
|
|
Role
Mac Address
748e.f8f9.6300
cc4e.2438.7280
+---+
+---+
+---+
|
|
Role
Mac Address
748e.f8f9.6300
cc4e.2438.7280 128 remote
Pri State
Comment
0 local
Ready
0 remote
Ready
0 remote
Ready
Pri State
Comment
0 local
Ready, member if reloaded
Ready, standby if reloaded
Ready, active if reloaded
received: 0
received: 0
received: 225
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01