Displaying Stack Module Information; Displaying General Or Detailed Information About Stack Members - Arris Ruckus ICX 7850 Series Configuration Manual

Fastiron stacking configuration
Table of Contents

Advertisement

TABLE 32 Field definitions for the show chassis command
Field
Power supply 1
Power supply 2
Fan 1 through Fan 4
Fan controlled temperature
Fan speed switching temperature thresholds (Speed 1, Speed 2)
Current temperature (by component)
Back 40G module Temperature Readings
Exhaust Side Temperature Readings
Intake Side Temperature Readings
Boot Prom MAC
Management MAC

Displaying stack module information

The show module command displays information about stack unit modules. Output resembles the following.
ICX7750-26Q Router# show module
Module
U1:M1
ICX7750-26QXG 20-port Management Module
U1:M2
ICX7750-QSFP 6-port QSFP 240G Module
U1:M3
ICX7750-6Q 6-port QSFP 240G Module
U2:M1
ICX7750-26QXG 20-port Management Module
U2:M2
ICX7750-QSFP 6-port QSFP 240G Module
U2:M3
ICX7750-6Q 6-port QSFP 240G Module
U3:M1
ICX7750-26QXG 20-port Management Module
U3:M2
ICX7750-QSFP 6-port QSFP 240G Module
U3:M3
ICX7750-6Q 6-port QSFP 240G Module
TABLE 33 Field definitions for the show module command
Field
Module
Status
Ports
Starting MAC

Displaying general or detailed information about stack members

You can display information about any member in a stack by entering show commands from the active controller console port. If
you enter show commands from a unit that is not the active controller, the information may not be displayed correctly.
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
Description
The status of the primary power supply
The status of the secondary power supply, if present
The status of the cooling fans, including speed, temperature reading,
temperature range, and airflow direction
Measured temperature reading
Operating ranges for fan speeds 1 and 2, with the shutdown
temperature indicated at the upper end of the temperature range for
speed 2
Current temperature readings, in degrees Centigrade, for CPU, left
fan, right fan, module fan, left power supply, right power supply, left
front, middle front, right front, and back 40 Gbps module
For the rear 40 Gbps module, current temperature, warning level
temperature, and shutdown level temperature
From the air exhaust side of the chassis, the current temperature
reading, the warning level temperature setting, and the shutdown
level temperature setting
The current temperature reading from the air intake side of the
chassis
The MAC address of the boot prom
For the active controller only, the management MAC address
Status Ports Starting MAC
OK
56
748e.f8f9.6300
OK
24
748e.f8f9.6315
OK
24
748e.f8f9.631b
OK
56
cc4e.2438.7280
OK
24
cc4e.2438.7295
OK
24
cc4e.2438.729b
OK
56
cc4e.2438.7500
OK
24
cc4e.2438.7515
OK
24
cc4e.2438.751b
Description
Identifies the module by stack unit ID, module number, and module
type
The status of this module
The number of ports in this module
The starting MAC address for this module
Stack Management