3.6.8.

Braking resistor / supply voltage C3H

The energy generated during braking operation is absorbed by the Compax3
storage capacity.
If this capacity is too small, the braking energy must be drained via a braking
resistor.
3.6.8.1

Connect braking resistor C3H

Connection of braking resistor - figure (see on page 53)
PIN
Designation
DBR+
+ Braking resistor
DBR-
- Braking resistor
Braking operation of Compax3HxxxV4
Controller type
Capacitance / storable energy
400V / 480V
Minimum braking- resistance
Maximum continuous current
Minimum line cross section:
Maximum line length:
Maximum output voltage:
3.6.8.2

Power supply voltage DC C3H

Connection of power voltage DC -figure (see on page 53)
PIN
Description
DC+
+ DC high voltage supply
DC-
- DC high voltage supply
Warning!
Do not connect any braking resistor on DC+/DC- .
192-120113 N08 C3I12T11 - December 2010
H050V4
H090V4
2600 µF
3150 µF
602 / 419 Ws
729 / 507 Ws
24 Ω
15 Ω
11 A
17 A
2
2.5mm
2m
830VDC
Compax3 device description
H125V4
H155V4
5000 µF
5000 µF
1158 / 806 Ws
1158 / 806 Ws
8 Ω
8 Ω
31 A
31 A
59