Motor / Motor Brake C3H - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Parker EME
3.6.5.

Motor / Motor brake C3H

Compax3H motor
cable
Motor connection clamps - figure (see on page 53)
PIN
Designation
M1/U
U (motor)
M2/V
V (motor)
M3/W
W (motor)
PE
PE (motor)
* depending on the cable type
A motor output filter is required for motor cables >50m. Please contact us.
Shielding connection of the motor cable
The motor cable should be fully shielded and connected to the Compax3 housing.
The shield of the motor cable must also be connected with the motor housing. The
fixing (via plug or screw in the terminal box) depends on the motor type.
Attention - Please wire the motor holding brake!
Connect the brake only on motors which have a holding brake! Otherwise
make no brake connections at all.
Requirements cables for motor holding brake
If a motor holding brake is present, one cable of the motor holding brake must
be fed on the device side through the toroidal core ferrite provided as
accessory ZBH0x/xx (63Ω @1MHz, di=5.1mm), in order to ensure error-free
switching on and off of the motor holding brake.
Connection of motor brake X3 - figure (see on page 55)
PIN
Designation
1
BR
2
GND
Motor holding brake output
Motor holding brake output
Voltage range
Maximum output current (short circuit
proof)
192-120113 N08 C3I12T11 - December 2010
Compax3 device description
Motor cable lead designation*
U / L1 / C / L+
1
V / L2
2
W / L3 / D / L-
3
YE / GN
YE / GN
Motor cable lead designation*
WH
4
BK
5
Compax3
21 – 27VDC
1.6A
U1
U2
U3
YE / GN
Br1
Br2
57