Connections On The Device Bottom - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Parker EME
3.5.2.

Connections on the device bottom

Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
Caution!
When the control voltage is missing there is no indication whether or not high
voltage supply is available.
Attention - PE connection!
PE connection with 10mm
Attention - hot surface!
The heat dissipator can reach very high temperatures (>70°C)
P
X40
X41
1
4
M
X43
2
4
3
Line cross-sections of the power connections (on the device bottoms)
Compax3 device:
Cross-section: Minimum... Maximum [with conductor sleeve]
M050, M100, M150
0.25 ... 4 mm
M300
0.5 ... 6 mm
PSUP10
Mains supply: 0.5 ... 6 mm
Braking resistor: 0.25 ... 4 mm
PSUP20 & PSUP30
Mains supply: 0.5 ... 16 mm
Braking resistor: 0.25 ... 4 mm
192-120113 N08 C3I12T11 - December 2010
2
via a grounding screw at the bottom of the device.
Mains module PSUP
Ballast resistor
Mains supply VAC/PE
Central ground connection for the axis system,
2
with 10mm
to the ground screw on the housing.
Fan*
Axis controller
Motor / Brake
Fixing for motor shield clamp
Fan*
optionally, the axis controller features a ground screw
on the housing, if the grounding is not possible via the
back plate.
* is internally supplied.
2
(AWG: 23 ... 11)
2
(AWG: 20 ... 10)
2
(AWG: 20 ... 10)
2
Compax3 device description
2
(AWG: 23 ... 11)
(AWG: 20 ... 6)
2
(AWG: 23 ... 11)
43

Hide quick links:

Advertisement

Table of Contents
loading