Parker EME
1.7

Conditions of utilization

In this chapter you can read about:

Conditions of utilization for CE-conform operation ........................................................... 19

Conditions of utilization for UL certification Compax3S .................................................... 22
Conditions of utilization for UL certification Compax3M .................................................... 23
Conditions of utilization for UL certification Compax3H .................................................... 24
Current on the mains PE (leakage current) ...................................................................... 25
Supply networks .............................................................................................................. 25
1.7.1.
Conditions of utilization for CE-conform operation
Mains filter:
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2004/108/EC and for electrical
operating devices for utilization within certain voltage limits 2006/95/EC are fulfilled
when the following boundary conditions are observed:
Operation of the devices only in the condition in which they were delivered,
In order to ensure contact protection, all mating plugs must be present on the
device connections even if they are not wired.
Please respect the specifications of the manual, especially the technical
characteristics (mains connection, circuit breakers, output data, ambient
conditions,...).
1.7.1.1

Conditions of utilization mains filter

A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the system mains input or separately
for each device or with C3M for each axis system.
Use of the devices in a commercial and residential area (limit value class in
accordance with EN 61800-3)
The following mains filters are available for independent utilization:
Device:
Compax3S
S0xxV2
S1xxV2,
S0xxV4, S150V4
S300V4
Device:
Compax3H
H050V4
H090V4
H1xxV4
192-120113 N08 C3I12T11 - December 2010
i.e. with all housing panels.
Limit value
Motor cable length
class
C2
< 10 m
C2
> 10 m, < 100 m
C2
< 10 m
C2
> 10 m, < 100 m
C3
< 10 m
C2, C3
> 10 m, < 100 m
Limit value
Motor cable length
class
C2
< 10 m
C2
> 10 m, < 50 m
C2
< 10 m
C2
> 10 m, < 50 m
C2
< 10 m
C2
> 10 m, < 50 m
Introduction
Mains filter
Order No.:
without
NFI01/01
without
NFI01/02
without
NFI01/03
Mains filter
Order No.:
without
NFI02/01
without
NFI02/02
without
NFI02/03