Measurement Of The Motor Temperature Of Compax3M (Axis Controller); Safety Technology Option For Compax3M (Axis Controller) - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Parker EME
3.5.8.

Safety technology option for Compax3M (axis controller)

Motor holding brake output
Motor holding brake output
Voltage range
Maximum output current (short circuit
proof)
Attention - Please wire the motor holding brake!
Connect the brake only on motors which have a holding brake! Otherwise make no
brake connections at all.
Requirements cables for motor holding brake
If a motor holding brake is present, one cable of the motor holding brake must be
fed on the device side through the toroidal core ferrite provided as accessory
ZBH0x/xx (63Ω @1MHz, di=5.1mm), in order to ensure error-free switching on
and off of the motor holding brake.
3.5.7.1
Measurement of the motor temperature of Compax3M
(axis controller)
Connector X15
The acquisition of the motor temperature by the axis controller can either take
place via the connection of X15 (Tmot) or via the feedback cable and the
corresponding connection on X13 PIN10.
Pin
Description
1
+5V
2
Sensor
The temperature acquisition on X15 Tmot can not be connected at the same
Connector X14
Pin
Description
1
STO1/
2
STO-GND
3
STO2/
4
STO-GND
Note!
If the Compax3M axis controller features a safety option, these connections must
also be wired, otherwise it is not possible to set up the axis.
192-120113 N08 C3I12T11 - December 2010
Compax3
21 – 27VDC
1.6A
time as X13 Pin 10.
+24VDC
GND
+24VDC
GND
Compax3 device description
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents