Connection Of The Digital Outputs/Inputs; Logic Proximity Switch Types - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Parker EME
Wiring of digital outputs
Compax3
F1
F2
24V
X12/1
X12/11
X12/2
18.2K Ω
0V
X12/15
The circuit example is valid for all digital outputs!
The outputs are short circuit proof; a short circuit
generates an error.
F1: Delayed action fuse
F2: Quick action electronic fuse; can be reset by switching the 24 VDC supply off and on again.
Type
1
Transistor switch
PNP
Logic
(N.O.)
"active high"
Description of logic Compax3 sees a
logical "1" upon
activation
Fail safe logic
no
Instruction for pull
-
up resistor in the
initiator
Connections
3.8.3.1

Connection of the digital Outputs/Inputs

SPS/
PLC
3.8.3.2

Logic proximity switch types

2
PNP
(N.C)
"active low"
Compax3 sees a
logical "0" upon
activation"
yes
-
Initiator
Compax3
X12/1 (+24 VDC)
X12/X (Input)
X12/15 (GND)
1)
When the connection between transistor emitter of the initiator and X12/15
(GND24V of the Compax3 )is lost, it can not be guaranteed, that the Compax3
detects a logical „0".
2)
The INSOR NPN types INHE5212 and INHE5213 manufactured by Schönbuch
Electronic do correspond to this specification.
192-120113 N08 C3I12T11 - December 2010
Status of digital inputs
Compax3
SPS/PLC
X12/1
X12/6
10nF
X12/15
The circuit example is valid for all digital inputs!
Signal level:
> 9.15V = "1" (38.2% of the control voltage applied)
< 8.05V = "0" (33.5% of the control voltage applied)
3
NPN
(N.O.)
"active low"
Compax3 sees a
logical "0" upon
activation"
Only conditional
Rmin=3k3
Rmax=10k
2)
Initiator
Compax3 device description
F2
F1
100K Ω
22K Ω
22K Ω
10K Ω
22K
4
NPN
(N.C)
"active high"
Compax3 sees a
logical "1" upon
activation
1)
no
Rmin=3k3
Rmax=10k
2)
X12/1 (+24 VDC)
X12/X (Input)
X12/15 (GND)
24V
0V
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents