3.6.1 Internal Resistor Setting
This drive has a built-in regeneration brake corresponding to the drive power.
Specifications of internal regeneration brake for each drive power are as follows.
Drive Power
100W
200W
400W
1KW
3.5KW

Table 15. Internal Resistor Setting

To use the regeneration broke built in the drive, you should set the brake in the
following order.
A. Regeneration brake wiring
- Check for B, BI terminal short (default short at the time of release from the
factory, 1kW or less)
Parker Hannifin
Internal
Internal Resistance
Resistance
100Ω
100Ω
100Ω
40Ω
12.6Ω
Power
50W
50W
50W
100W
150W