Ramp Upon Error / Deenergize - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Parker EME
Jerk
3
Unit: Unit/s
Range: 0 ... 10 000 000
STOP delay
After a STOP signal, the drive applies the brakes with the delay that is set (2).
Please observe:
The configured STOP ramp is limited. The STOP ramp will not be smaller than the
deceleration set in the last motion set.
NO STOP: no STOP (I1, M.I6, CW.1 or CW.14)
4.1.8.2

Ramp upon error / deenergize

Ramp (delay) upon error and "De-energize"
The same delay is used for "Deenergizing" and when an error appears (errors
which do not deenergize immediately).
3
QUIT
3: Deceleration on "de-energize" and on "error".
Please observe:
The configured error ramp is limited. The error ramp will not be smaller than the
deceleration set in the last motion set.
ACKN: I0: Quit or CW.0 (with positive edge)
START: M.E5: START or CW.13 (with positive edge)
192-120113 N08 C3I12T11 - December 2010
Setting up Compax3
Standard value:
1 000 000
3
129