Introduction
Motor and Feedback
cable:
Compax3S motor
cable
Compax3H motor
cable
Compax3M motor
cable
Compax3 encoder
cable:
Compax3M encoder
cable:
Cable for Compax3S,
Compax3M
20
Use of the devices in the industrial area (limit values class C3 in accordance
with EN 61800-3)
The following mains filters are available for independent utilization:
Device: PSU
P10
P10
P20
P30
Connection length: Connection between mains filter and device:
unshielded:
< 0.5 m
shielded
< 5 (fully shielded on ground - e.g. ground of control cabinet)
1.7.1.2

Conditions of utilization for cables / motor filter

Operation of the devices only with motor and feedback cables whose plugs
contain a special full surface area screening.
< 100 m (the cable should not be rolled up!)
A motor output filter (see on page 336) is required for motor cables >20 m:
MDR01/04 (max. 6.3 A rated motor current)
MDR01/01 (max. 16 A rated motor current)
MDR01/02 (max. 30 A rated motor current)
A motor output filter is required for motor cables >50m. Please contact us.
<80m per axis (the cable must not be rolled up!)
The entire length of the motor cable per axis combination may not exceed 300m.
A motor output filter (see on page 336) is required for motor cables >20 m:
MDR01/04 (max. 6.3 A rated motor current)
MDR01/01 (max. 16 A rated motor current)
MDR01/02 (max. 30 A rated motor current)
Shielding connection of the motor cable
The cable must be fully-screened and connected to the Compax3 housing. Use the
cable clamps/shield connecting terminals furnished with the device.
The shield of the cable must also be connected with the motor housing. The fixing
(via plug or screw in the terminal box) depends on the motor type.
< 100 m
< 80m
Corresponding to the specifications of the terminal clamp with a temperature range
of up to 60°C.
192-120113 N08 C3I12T11 - December 2010
Limit value
Reference: Axis system
class
with motor cable
C3
< 6 x 10 m
C3
< 6 x 50 m
C3
< 6 x 50 m
C3
< 6 x 50 m
C3I12T11
Mains filter
Order No.:
NFI03/01
NFI03/02
NFI03/03
NFI03/03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents