Setting up Compax3
246
4.4.7.4

Tips

Tip
Problem
1
Speed too low
(with reverse operation)
2
Speed too low
(with continuous operation)
3
Test movement missing
4
No error detected
5
Speed too low and amplitude of
the excitation signal too small
(with reverse operation)
Speed too low and
6
amplitude of the excitation
signal too small
(with continuous operation)
Test movement missing
7
amplitude of the excitation
signal too small
8
amplitude of the excitation
signal too small
9
Following error occurred
*if the travel range is too short, the speed is not increased, as the drive does not
reach the maximum speed.
192-120113 N08 C3I12T11 - December 2010
Measures
Increase maximum speed and adapt travel
range*
Increase maximum speed
A test movement is important for drives with
high friction or with mechanical slack points
(play).
Please note the boundary conditions (see
on page 244).
Increase amplitude of the excitation signal;
increase maximum speed and adapt travel
range*
Increase amplitude of the excitation signal;
increase maximum speed.
Increase amplitude of the excitation signal
or / and
activate an appropriate test movement
Increase the amplitude of the excitation
signal.
Increase the parameter "permissible
following error" or decrease the amplitude of
the excitation signal.
C3I12T11