Conditions Of Utilization For Ul Certification Compax3S - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Introduction
1.7.2.

Conditions of utilization for UL certification Compax3S

22
UL certification for Compax3S
conform to UL:
Certified
The UL certification is documented by a "UL" logo on the
device (type specification plate).
Conditions of utilization
The devices are only to be installed in a degree of contamination 2 environment
(maximum).
The devices must be appropriately protected (e.g. by a switching cabinet).
The X2 terminals are not suitable for field wiring.
Tightening torque of the field wiring terminals ( green Phoenix plugs)
C3S0xxV2
C3S1xxV2,
C3S0xxV4, C3S150V4
C3S300V4
Temperature rating of field installed conductors shall be at least 60°C Use copper
lines only
Please use the cables described in the accessories chapter (see on page 323,
see on page 324), they feature a temperature rating of at least 60°C.
Maximum Surrounding Air Temperature: 45°C.
Suitable for use on a circuit capable of delivering not more than 5000 rms
symmetrical amperes and 480 volts maximum.
ATTENTION
Danger of electric shock.
Discharge time of the bus condenser is 10 minutes.
The drive provides internal motor overload protection.
This must be set so that 200% of the motor nominal current are not exceeded.
Cable cross-sections
Mains input: corresponding to the recommended fuses.
Motor cable: corresponding to the Nominal output currents (see on page 375,
see on page 376)
Maximum cross-section limited by the terminals mm
C3S0xxV2
C3S1xxV2,
C3S0xxV4, C3S150V4
C3S300V4
Circuit breaker
In addition to the main circuit breaker, the devices must be equipped with a S271
K or S273 K circuit breaker with K characteristic made by ABB.
C3S025V2: ABB, nom 480V 10A, 6kA
C3S063V2: ABB, nom 480V, 16A, 6kA
C3S100V2: ABB, nom 480V, 16A, 6kA
C3S150V2: ABB, nom 480V, 20A, 6kA
C3S015V4: ABB, nom 480V, 6A, 6kA
C3S038V4: ABB, nom 480V, 10A, 6kA
C3S075V4: ABB, nom 480V, 16A, 6kA
C3S150V4: ABB, nom 480V, 20A, 6kA
C3S300V4: ABB, nom 480V, 25A, 6kA
192-120113 N08 C3I12T11 - December 2010
according to UL508C
E-File_No.: E235342
"UL" logo:
0.57 - 0.79Nm
0.57 - 0.79Nm
1.25 - 1.7Nm
2
/ AWG
2
2.5mm
AWG 12
2
4.0mm
AWG 10
2
6.0mm
AWG 7
C3I12T11
5 - 7Lb.in
5 - 7Lb.in
11 - 15Lb.in