Compax3 device description
Caution!
Caution!
36
Mains connection Compax3S1xxV2 3AC
Controller type
Supply voltage
Input current
Maximum fuse rating per device
(=short circuit rating)
* for UL conform operation (see on page 22), a miniature circuit breaker, K
characteristic, Type S203 is to be used.
The 3AC V2 devices must only be operated with three phases!
Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
3.3.5.2

Braking resistor / high voltage DC C3S connector X2

The energy generated during braking operation is absorbed by the Compax3
storage capacity.
If this capacity is too small, the braking energy must be drained via a braking
resistor.
Braking resistor / high voltage supply plug X2 for 1AC
230VAC/240VAC devices
PIN
Designation
1
factory use
2
- braking resistor (not short-circuit protected!)
3
PE
4
+ braking resistor (not short-circuit protected!)
5
factory use
Braking operation Compax3S0xxV2 1AC
Controller type
Capacitance / storable energy
Minimum braking- resistance
Recommended nominal power rating
Maximum continuous current
The power voltage DC of two Compax3 1AC V2 devices (230VAC/240VAC
devices) must not be connected.
192-120113 N08 C3I12T11 - December 2010
S100V2
S150V2
Three phase 3* 230VAC/240VAC
80-253VAC / 50-60Hz
10Arms
13Arms
16A
20A
MCB miniature circuit breaker, K characteristic
S025V2
S063V2
560µF / 15Ws
1120µF / 30Ws
100Ω
56Ω
20 ... 60W
60 ... 180W
8A
15A
C3I12T11