Control Voltage 24 Vdc C3H; Mains Connection Compax3H - Parker Compax3 Operating Instructions Manual

Positioning via digital i/os & com port
Hide thumbs Also See for Compax3:
Table of Contents

Advertisement

Compax3 device description
3.6.6.

Control voltage 24 VDC C3H

3.6.7.

Mains connection Compax3H

Device protection
58
Connection of control voltage 24VDC figure (see on page 55)
Connector
Descripti
X4 Pin
on
1
NC
2
GND24V
3
+24 V
Control voltage 24VDC Compax3S and Compax3H
Controller type
Voltage range
Current drain of the device
Total current drain
Ripple
Requirement according to safe extra
low voltage (SELV)
Short-circuit proof
Avoid permanent switching on and off so that the charging connection is not
overloaded. Therefore wait at least 1 minute before switching on the device
Connection of mains voltage figure (see on page 53)
Mains connection Compax3HxxxV4 3*400VAC
Device type Compax3
Supply voltage
Input current
Output current
Maximum fuse rating per
device(=short circuit
rating)
Branch circuit protection
according to UL
Mains connection Compax3HxxxV4 3*480VAC
Device type Compax3
Supply voltage
Input current
Output current
Maximum fuse rating per
device(=short circuit
rating)
Branch circuit protection
according to UL
192-120113 N08 C3I12T11 - December 2010
NC
GND
24 VDC (power supply)
Compax3
21 - 27VDC
0.8 A
0.8 A + Total load of the digital outputs + current
for the motor holding brake
0.5Vpp
yes
conditional (internally protected with 3.15AT)
again.
H050V4
H090V4
Three-phase 3*400VAC
350-528VAC / 50-60Hz
66Arms
95Arms
50Arms
90Arms
80A
100A
JDDZ Class K5 or H
JDRX Class H
H050V4
H090V4
Three-phase 3*480VAC
350-528VAC / 50-60Hz
54Arms
82Arms
43Arms
85Arms
80A
100A
JDDZ Class K5 or H
JDRX Class H
C3I12T11
H125V4
H155V4
143Arms
164Arms
125Arms
155Arms
160A
200A
H125V4
H155V4
118Arms
140Arms
110Arms
132Arms
160A
200A