Click the Line icon and then left- click where you want the line to start and end on the
image. Right-click to finish drawing the area.
Click the Frame icon and then left- click where you want the line to start and end on the
image. Right-click to finish drawing the area.
Delete all points, lines, and frames on the image.
Note: You can draw up to a total of 10 points, 1 line, and 10 frames.
3. Set the temperature measurement rules for the point/line/frame just created.
Select the check box of the first rule and enter the following information about this
rule. You can set up to up to 21 rules (10 points, 1 line, and 10 frames).
Name: Enter the desired name for the rule.
Type: Select Point, Line, or Frame as the rule type.
Point: This is the temperature of the point you inserted in the live view image.
Line: This is the temperature of the line you drew in the live view image.
Frame: This is the temperature of the area you drew in the live view image.
Emissivity: Set the emissivity (ability to emit infrared energy) of your target.
Values range from 0 (completely reflective target) to 1 (object emitting no
infrared energy).
Distance (m): Enter the straight-line distance between the target and the
device.
Reflective Temperature: If there are any targets with high emissivity in the
scene, select the check box and set the reflective temperature to correct the
temperature. Default is unchecked.
TruVision IP Thermal Camera Configuration Manual
49