2. Select the check boxes of the interface to set the temperature measurement
configurations.
 Enable Temperature Measurement: Select the check box to enable
temperature measurement function.
 Display Temperature Info. on Stream: Select the check box to display
temperature information in live view.
 Add Original Data on Capture: Select the check box to add original data on
capture.
 Add Original Data on Stream: Select the check box to add original data on
stream.
 Data Refresh Interval: Select the data refresh interval from 1s to 5s.
 Unit: Display temperature in Degree Celsius, Degree Fahrenheit, or Degree
Kelvin.
 Temperature Range: Select the temperature range: -20 to 150 °C, -4 to 302 °F,
or 253 to 423 K.
 Emissivity: Set the emissivity (ability to emit infrared energy) of your target.
Values range from 0 (completely reflective target) to 1 (object emitting no
infrared energy).
Note: The emissivity of each object is different.
 Distance: Manually enter the straight-line distance between the target and the
device.
3. Click
Save
to save the settings.
4. From the Local Configuration panel, click
Temperature Info. on
TruVision IP Thermal Camera Configuration Manual
Local Configuration
Camera. The option is disabled by default.
and enable
Display
47