Heater Gontrol Panel
Overhaul
AIR MIX CONTROL CABLE
Adiustment, page 21'23
HEATER FAN SWITCH
Test, page 21-27
Air Mix Control Cable Replacement
1. Cut the inner cable on the lever side ofthe cable holder, then remove both pieces ofthe inner cable.
2. Using a sharp knife, cut completely lhrough the end of the cable housing at the two locations.
3. Slidethe large section ofthecable housing outofthecable holder, being careful not to da mage the cable stops.
4. Carefully remove the cut pieces of the cable housing with a small flat tip screwdriver.
5. Hook the tip of the new air mix control cable to the temperature control lever, then push the cable housing into the
cable holder until it locks into place.
g
\ n 4 . - - -
^Jj-
6:B
ffi
^gvry
f f i \
AIR MIX CONTROL CABLE
CAALE HOLDER
TEMPERATURE
CONTFOL LEVER
NOTE: After assem bly, check that the temperatu re control lever slides smoothly through the full stroke from rightto left.
2 1 - 2 2