Mode Control Motor
Mode control motoa does nol run,
or one or more modes are inoPen_
tive.
check the No. 17 (7.5 A) fuse in
the under'dash fuse/relay box.
ReDlace the lus€, and rech€ck.
Chsck toJ an open in the wire:
1. Disconnect the mode control
motor 7P connector,
2. Turn the ignition switch ON (ll).
3. Measure the voltage between
the No. l terminal and body
grou no.
Repair open in the wi.e between
the No. 17 fuse and the mode
control motor,
ls lhere battery voltage?
Check tor an open in the wite:
1. Turn the ignition switch OFF.
2. Check tor continuity between
the No.7 terminal ofthe mode
control motor 7P connector
and body ground.
Check for an opon in the wire
h$ro6n the modc control motor
and body ground.lllho wire is OK,
check lor poor gaound tl G,Ol and
G402.
Test the mode control motor (soe
page 21-24).
Check the mode control linkage
and doors:
1 . R e m o v e t h e m o d e c o n t r o l
motor (see page 21 24).
2. Check the mode control linkage
and doors for smooth move-
ment.
lsthe mode control motor OK?
Do the mode control iinkage
and doors move smoothly?
Roolace the mode control motor.
MODE CONTROL MOTOR 7P CONNECTOR
WIRE SIDE OF FEMALE TERMINALS
T o p a g e 2 1 - 1 2
f
3
I
5
BLK/YEL
_
l
T
1
I
6
7
BLK
{ l
(cont'd)
2 1- 11