Homing depending on the home switch and positive limit switch (
Mode 26
Circumstance 1: MC_Home instruction is executed while the home switch is OFF and the axis starts to
move in the positive direction at the first-phase speed. The axis moves at the
second-phase speed when the home switch is ON. Where the axis stands is the home
position when the home switch is OFF.
Circumstance 2: MC_Home instruction is executed while the home switch is ON and the axis moves in
the positive direction at the second-phase speed. Where the axis stands is the home
position when the home switch is OFF.
Circumstance 3: MC_Home instruction is executed while the home switch is OFF. The axis moves in
the positive direction at the first-phase speed. The motion direction changes and the
axis moves at the first-phase speed when the home switch is OFF and the positive
limit switch is ON. The motion direction changes again and the axis moves at the
second-phase speed when the home switch is ON. Where the axis stands is the home
position when the home switch is OFF.
Appendix D Explanation of Homing Modes
25
: mode 25)
E
A
D_
D-19