Delta Electronics DVP15MC11T Operation Manual page 254

Table of Contents

Advertisement

Output Update Timing
Parameter Name
Done
Busy
Active
Error
Timing Chart
E xec ute
Done
Bus y
Ac tive
Error
E rro rID
Case 1: Busy and Active change to TRUE when Execute changes from FALSE to TRUE and one
period later, Done changes to TRUE. When Done changes to TRUE, Busy and Active change
to FALSE. When Execute changes from TRUE to FALSE, Done changes from TRUE to
FALSE.
Case 2: Before DMC_WriteParameter_CANopen is executed, the input parameter value such as axis
No: 0 is illegal. After Execute changes from FALSE to TRUE, Error changes from FALSE to
TRUE and ErrorID shows corresponding error codes. As Execute changes from TRUE to
FALSE, Error changes from TRUE to FALSE and the content of ErrorID is cleared to 0.
Function
DMC_WriteParameter_CANopen is used to set the parameter value of a slave. Users can specify the index
and subindex of the parameter which is to be set.
Programming Example
Below is an example of one DMC_WriteParameter_CANopen instruction execution.
The variable table and program
Variable name
ReadPm_C1
Timing for changing to TRUE
 When the writing of the
parameter content is completed
 When Execute changes to TRUE
 When the slave starts being
controlled by the instruction
 When an error occurs in the
instruction execution or the input
parameters for the instruction are
illegal
Ca se1
Data type
DMC_ReadParameter_CANopen
Chapter 8 Logic Instructions
Timing for changing to FALSE
 When Execute changes from
TRUE to FALSE after the
instruction execution is completed
 When Error changes to TRUE
 When Done changes from FALSE
to TRUE
 When Error changes to TRUE
 When Done changes from FALSE
to TRUE
 When Execute changes from
TRUE to FALSE
Cas e2
Initial value
8_
8-183