DVP15MC11T Operation Manual
8.7.3
CTUD
FB/FC
FB
CTUD is used as an up-down counter.
Parameters
Parameter
name
Up-counter
CU
input signal
Down-counter
CD
input signal
Reset
Reset signal
Load
Load signal
PV
Preset value
QU
Output signal
QD
Output signal
CV
Counter value
_8
●
CU
●
CD
●
Reset
●
Load
PV
●
QU
●
QD
CV
8-50
Explanation
Input/
Meaning
Output
Input
Input
Input
Input
Input
Output
Output
Output
Bit string
CTUD_inst ance
CTUD
EN
E NO
CU
Q U
CD
Q D
Rese t
CV
Load
PV
Description
Control the counter to count up
Control the counter to count down
Reset counter present value
For writing the down-counter value
Counter setting value
Q is TRUE when CV equals PV.
Q is TRUE when the counter counts down
to 0.
Counter present value
Integer
●
●
Applicable
model
DVP15MC11T
Valid range
TRUE or FALSE
TRUE or FALSE
TRUE or FALSE
TRUE or FALSE
0 ~ 4294967295
TRUE or FALSE
TRUE or FALSE
0 ~ 4294967295
Real
Time, date
number