Delta Electronics DVP15MC11T Operation Manual page 466

Table of Contents

Advertisement

CombineMode is set to 1
���������������� ������������������ ���� ���������� �������� =
= Position variation of Master axis1 ×
GearRatioNumeratorM2
GearRatioDenominatorM2
The master gear ratio numerator and denominator are the factors to adjust the position variations of
two master axes. See the formula above.
MasterValueSource can be set to 0 (command position) and 1 (actual position) so as to specify the
source of the position variation. If the value is set to 0, add up the master axis command position
variations. If the value is set to 1, subtract one master axis actual position variation from another
master axis actual position variation.
The Acc, Dec and Jerk indicate that the master axis has been in motion before the instruction is
executed. If the instruction is executed at the moment, the slave axis will speed up or down
according to the set acceleration, deceleration and jerk so as to realize the synchronization with the
master position variations. When the synchronization is achieved, InSync is TRUE and the
instruction execution is completed.
Use other motion instruction (such as MC_Stop instruction) for the control over the slave axis so as
to end the master-slave axis relationship in the instruction. Set the value of BufferMode of other
motion instruction which has the Buffermode parameter to 0 in order to abort the MC_CombineAxes
instruction and disconnect the master-slave axis relationship.
If the master axis gear ratio is to be switched during the motion, use another MC_CombineAxes
instruction to abort the MC_CombineAxes instruction which is being executed.
Programming Example
The example of executing the MC_CombineAxes instruction is described as below.
1.
The variable table and program
Variable name
Pwr1
Axis1
Pwr1_BM
Pwr1_Sta
Velocit y
GearRatioNumeratorM1
GearRatioDenominatorM1
Veloc it y
MC_Buffer_Mode
Slav e ax is
Mas ter a xis 1
Mas ter a xis 2
− Position Variation of Master axis2 ×
Mas ter a xis 1
Mas ter a xis 2
Slav e ax is
Data type
MC_Power
USINT
BOOL
Chapter 12 Troubleshooting
Time
Time
Initial value
1
1
11-143
11