Delta Electronics Programmable Logic Controller DVP-EH2-L Instruction Sheet

Delta Electronics Programmable Logic Controller DVP-EH2-L Instruction Sheet

Delta electronics programmable logic controller instruction manual

Advertisement

Quick Links

Warning
This instruction sheet only provides introductory information on electrical specifications, functions, and wiring. The
program and instructions designed for DVP-EH2-L are compatible with those of DVP-EH2 series, and please refer to
"DVP-PLC Application Manual: Programming". For how to purchase its peripheral devices, please refer to this
instruction sheet or "DVP-PLC Application Manual: Special Modules".
DVP-EH2-L is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust,
humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device
(e.g. key or specific tools are required for opening the enclosure) in case danger and damage on the device may
occur.
DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all
the wiring again before switching on the power and DO NOT touch any terminal when the power is switched on.
Make sure the ground terminal
is correctly grounded in order to prevent electromagnetic interference.
Introduction
Product Profile & Outline
1
Battery socket cover
2
3
4
2
Function card/memory card cover
3
I/O terminals
1
5
4
I/O terminal No.
6
5
Extension module connection port cover
7
6
Input indicator
7
Output indicator
9
1 0
8
DIN rail clip
9
Communication port cover
4
8
8
3
10 DIN rail (35mm)
1 0
5
2
6
1
7
1
3
9
2
8
1 1
4
1 2
1
Mounting screw
5
Memory card port
9
COM1 (RS-232)
2
Direct mounting hole
6
POWER/RUN/BAT.LOW/ERROR indicator
10
COM2 (RS-485)
3
Battery socket
7
Extension module connection port
11
Run/Stop switch
4
Function card mounting hole
8
Left-side Extension module connection port
12
VR0/VR1
Dimension
. 2
0
8
9
9
7
1 2 9 . 2
1 4 8
Specifications
Electrical Specification
Model
32EH00 2-L
Item
Power supply voltage
100 ~ 240VAC (-15% ~ 10%); 50/60Hz ± 5%
Fuse capacity
2A/250VAC
Power consumption
60VA
DC24V current supply
500mA
Power protection
DC24V; output short-circuited
Withstand voltage
1,500V AC (Primary-Secondary); 1,500V AC (Primary-PE); 500V AC (Secondary-PE)
Insulation resistance
> 5M (all I/O point-to-ground: 500V DC)
ESD: 8KV Air Discharge; EFT: Power Line: 2KV, Digital I/O: 1KV, Analog &
Noise immunity
Communication I/O: 250V; Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV,
RS: 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire shall not be less than that of L, N terminal of the power.
Earth
(When many PLCs are in use at the same time, please make sure every PLC is properly
grounded.)
Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2
Operation/storage
Storage: -25 ºC ~ 70 ºC (temperature); 5 ~ 95% (humidity)
International standards:IEC61131-2,IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC68-2-27
Vibration/shock immunity
(TEST Ea)
Weight (g)
R/T: 670/636
Input Point Specification
Specification
24VDC single common port input
Items
10kHz
20kHz
60kHz
Input wiring type
Change wiring from S/S to SINK or SOURCE
Input indicator
LED display; light on = ON, light off = OFF
Input voltage (±10%)
24VDC
Input point configuration
*3
*1
*2
Input impedance
4.7k
3.3k
4.7k
> 4mA (16.5V)
> 6mA (18.5V)
> 4mA (16.5V)
Off
On
Active Level
On
Off
< 1.5mA (8V)
< 2.2mA (8V)
< 1.5mA (8V)
Off
On
< 8us
< 3.5us
< 7.5us
Response time/
noise immunity
On
Off
< 60us
< 20us
< 7.5us
Output Point Specification
ENGLISH
Single common port transistor output
Specification
Items
Low speed
High speed*
Max. frequency
10kHz
200kHz
Output indicator
LED display; light on = ON, light off = OFF
Min. load
--
Working voltage
5 ~ 30V DC
Insulation
Photo coupler isolation
< 1kHz, 0.3A/1 point @ 40°C
Current specification
0.3A/1 point @ 40ºC
≥ 1kHz, 30mA/1 point @ 40°C
Off
On
20us
Max. output
0.2us
delay time
On
Off
30us
Over-current protection
N/A
Mechanical life
N/A
Electrical life
N/A
* Only Y0 and Y2 support high-speed output.
Installation & Wiring
3.1 How to Mount & Wiring Notes
How to install DIN rail:
DVP series PLC can be secured to a cabinet by using the DIN rail of 35mm in height and
7.5mm in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop any
side-to-side movement of PLC and reduce the chance of wires being loosen. A small retaining
clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the rail and gently
push it up. To remove it, pull the retaining clip down and gently remove PLC from DIN rail, as
shown in the figure.
How to screw: Please use M4 screw according to the dimension of the product.
> 50mm
Please install PLC in an enclosure with sufficient space around it to allow heat
DVP MPU
dissipation as shown in the figure.
> 50mm
> 50mm
> 50mm
Wiring:
1. Use O-type or Y-type terminal. See the figure in the left hand side for its
specification. PLC terminal screws should be tightened to 5 ~ 8 kg-cm (4.3 ~
Below 6.2
6.9 in-Ibs) and please use only 60/75ºC copper conductor.
2. DO NOT wire empty terminal • . DO NOT place the input signal cable and
To suit M3.5 screw terminals
output power cable in the same wiring circuit.
3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring.
Below 6.2
Tear off the sticker on the heat dissipation hole for preventing alien
substances from dropping in, to ensure normal heat dissipation of the PLC.
3.2 Wiring Notes
Power Input Wiring
The power input of DVP-EH2-L PLC is AC. When operating the PLC, please make sure that:
1. The input voltage should be current and its range should be 100 ~ 240V AC. The power should be
connected to L and N terminals. Wiring AC110V or AC220V to +24V terminal or input terminal will result in
serious damage on the PLC.
2. The AC power input for PLC MPU and I/O extension modules should be ON or OFF at the same time.
3. Use wires of 1.6mm (or longer) for the grounding. The power shutdown of less than 10ms will not affect the
operation of the PLC. However, power shutdown time that is too long or the drop of power voltage will stop
the operation of the PLC and all outputs will go OFF. When the power supply turns normal again, the PLC
will automatically return to its operation. Please be aware of the latched auxiliary relays and registers inside
the PLC when programming.
100~240
VAC
8 2 . 2
Unit: mm
Safety Wiring
Since a PLC controls many devices, actions of any device may affect actions of other devices, and the
breakdown of any one device may cause the breakdown of the whole auto-control system and danger.
Therefore, we suggest you wire a protection circuit at the power input terminal, as shown in the figure below.
5
MC
1
4
8
2
Guar d
Limit
MC
3
MC
1
L
N
7
6
Input Point Wiring
There are two types of DC inputs, SINK and SOURCE.
Input point loop equivalent circuit
DC Signal IN
S/S
+24V
Sinking
24G
Note
X0
*1: The bandwidth of input points
SINK mode
X10, X11, X14, and X15 is
20kHz.
(common port for current input S/S)
*2: The bandwidth of input points
Input point loop equivalent circuit
DC Signal IN
X0, X1, X4, and X5 is 60kHz.
*3: The bandwidth of the input
X0
+24V
points other than the
high-speed input points listed
24G
above is 10kHz.
S/S
*4: Input points X0 ~ X7and X10 ~
S/S
Sourcing
X17 can conduct 10 ~ 60ms
X0
digital filter adjustment.
SOURCE mode
(common port for current output S/S)
Output Point Wiring
Relay (R) contact circuit wiring
Single common port relay output
DVP-**-**-**-R
Load ON/OFF control
LOAD
Y0
2mA/DC power supply
LED
POWER
RY
< 250V AC, 30V DC
C0
Magnetic isolation
2A/1 point (5A/COM)
RELAY OUTPUT
75VA (conductive), 90W (resistive)
10ms
Flywheel diode: To extend the life span of contact
Fuse: Uses 5 ~ 10A fuse at the common port of output contacts to protect the output circuit
2×10
7
times (without load)
5
Varistor: To reduce the interference on AC load
1.5×10
times (5A 30V DC)
5
5×10
times (3A 120V AC)
DC power supply
4
3×10
times (5A 250V AC)
A C power supply
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC
internal program, to ensure safety protection in case of any unexpected errors.
Transistor (T) contact circuit wiring
1. NPN
Y0
< 0.3A
LED
C0
TRANSISTOR OUTPUT
2. PNP
Up0
< 0.3A
LED
Y0
ZP 0
TRANSISTOR OUTPUT
DC power supply
Circuit protection fuse
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC
internal program, to ensure safety protection in case of any unexpected errors.
注 意 事 項
DVP-PLC
AC Power Input
0.5A is the maximum power supply for
+24V power supply output terminal. DO
NOT connect other external power
supplies to this terminal. Every input
terminal requires 6 ~ 7mA to be driven;
e.g. the 16-point input will require
approximately 100mA. Therefore, +24V
cannot give output to extermal load that is
產 品 簡 介
more than 400A.
產 品 外 觀 及 各 部 介 紹
AC power supply load
1
Power circuit protection fuse (3A
Power indicator
Emergency stop
This button can cut off the system power supply when accidental
emergency takes place.
System circuit isolation device
The device is made of electromagnetic contactor and relay as the
9
switch to prevent the instability of system when the power is
intermittently supplied.
DVP-PLC (main processing unit)
4
Earth
Power supply AC: 100 ~ 240VAC
Wiring loop
1
SINK
24VDC
+5V
S/S
3
X0
+24V
24G
S/S X0
X1
X2
9
Sink Type
2
Wiring loop
1
SOURCE
24VDC
+5V
2
3
4
+24V
24G
S/S X0
X1
X2
Source Type
外 觀 及 尺 寸
5
2
C0 Y0 Y1
C1 Y3 Y4 C2 Y6 Y7
9
3
3
1
. 2
6
8
9
2
M C1
M C2
10
8
4
7
Emergency stop: Uses external switch
規 格
Empty terminal: not in use
電 氣 規 格
Neon indicator
Incandescent light (resistive load)
DC24V
5
5
C0 Y0
Y1 C1 Y4 Y5 Y6
Y7
LOAD
MC1
MC2
4
4
1
2
3
3
/
5
5
, (g)
Up 0 Zp 0
Y0
Y 1
Up 1 Zp 1
Y 10
Y11
MC1
MC2
輸 入 點 規 格
LOAD
4
1
3
3
2
Emergency stop
(±10%)
Flywheel diode + inductive load
Off On
On Off
Off On
On Off
DVP-EH2
DVP-PLC
(OPEN TYPE)
1
2
4
3
2
3
5
4
6
5
7
6
7
1 0
8
DIN
9
8
3
8
10
DIN
(35mm)
1 0
5
2
6
7
1
8
1 1
4
1 2
5
9 COM1 (RS-232)
6
10 COM2 (RS-485)
7
11 Run/Stop
8
12 VR0/VR1
0
9
7
1 2 9 . 2
8 2 . 2
1 4 8
mm
DVP32EH00 2-L
100 ~ 240V AC (-15% ~ 10%); 50/60Hz ± 5%
2A/250V AC
60VA
500mA
DC24V
1,500V AC (Primary-Secondary); 1,500V AC (Primary-PE); 500V AC (Secondary-PE)
5 M
500V DC
ESD: 8KV Air Discharge; EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O:
250V; Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m
L, N
PLC
0°C ~55°C
50 ~ 95%
2
-25°C ~70°C
5 ~ 95%
IEC 61131-2, IEC 68-2-6 (TEST Fc) / IEC 61131-2 & IEC 68-2-27 (TEST Ea)
R/T: 670/636
24VDC
10kHz
20kHz
60kHz
S/S
SINK
SOURCE
LED
ON
OFF
*
1
X10, X11, X14, X15
20kHz
24V DC
*
2
X0, X1, X4, X5
*
3
*
1
*
2
60kHz
4.7k
3.3k
4.7k
*
3
10kHz
> 4mA (16.5V)
> 6mA (18.5V)
> 4mA (16.5V)
*
4
X0~X17
10 ~ 60
< 1.5mA (8V)
< 2.2mA (8V)
< 1.5mA (8V)
ms
< 8 us
< 3.5 us
< 7.5 us
< 60 us
< 20 us
< 7.5 us

Advertisement

loading

Summary of Contents for Delta Electronics Programmable Logic Controller DVP-EH2-L

  • Page 1 Dimension Specifications Electrical Specification Item Power supply voltage Fuse capacity Power consumption DC24V current supply Power protection Withstand voltage Insulation resistance Noise immunity Earth Operation/storage Vibration/shock immunity Weight (g) Input Point Specification Items Input wiring type Input indicator Input voltage (±10%) Input point configuration Input impedance Active Level...