Delta Electronics DVP15MC11T Operation Manual page 101

Table of Contents

Advertisement

DVP15MC11T Operation Manual
8.5.2
LE
FB/FC
LE is used for a less- than or equal comparison of two or more variables or
FC
constants.
Parameters
Parameter
name
Comparison
In1 to InN
data
Comparison
Out
result
In1
to
InN
Out
Note:
_8
The symbol ● indicates that the parameter is allowed to connect to the variable or constant of the data type.
Function Explanation
LE is used for a less than or equal comparison of two or more variables or constants. if In1 ≤ In2≤ ...
≤ InN, Out is TRUE. Otherwise, Out is FALSE.
The input parameters In1~InN are allowed to be the variables of different data types in this
instruction when the data types of input variables are not BOOL, TIME, DATE, TOD and STRING.
When the data type of one input variable is one of BOOL, TIME, DATE, TOD and STRING, input
parameters In1~InN are all required to be of the data type. For example, if the data type of In1 is
TIME, the data type of In2~InN must be TIME. Otherwise, an error will occur in the compiling of the
software.
8-30
Input/
Meaning
Output
The number of comparison data can be
increased or decreased through the
programming software. Maximum: 8.
Input
Minimum: 2. That is N=2 ~ 8.
Output
Comparison result
Bit string
Explanation
LE
EN
ENO
In1
Ou t
.
.
.
.
.
.
InN
Description
Integer
Applicable
DVP15MC11T
Valid range
Depends on the data type
of the variable that the
input parameter is
connected to.
Depends on the data type
of the variable that the
output parameter is
connected to.
Real
Time, date
number
model

Hide quick links:

Advertisement

Table of Contents
loading