LIGHTS/METERS/SWITCHES
SERVICE INFORMATION
GENERAL
ACAUTION
A halogen head light bulb becomes very hot while the head light is on, and remains hot for awhile after it is turned off.
Be sure to let it cool down before servicing.
Note the following when replacing the halogen headlight bulb.
- Wear clean groves while replacing the halogen headlight bulb. Do not put fingerprints on the headlight bulb, as they
may create hot spots on the bulb and cause it to fail.
- If you touch the bulb with your bare hands, clean it with a cloth moistened with alcohol to prevent its early failure.
- Be sure to install the dust cover after replacing the bulb.
Check the battery condition before performing any inspection that requires proper battery voltage.
A continuity test can be made with the switches installed on the scooter.
Route the wires and cables properly after servicing each component (page 1-14).
The following color codes used are indicated through out this section.
Bu
Bl:
Br:
: Blue
Black
Brown
G: Green
Gr: Gray
Lb: Light Blue
Lg
0:
R:
: Light Green
Orange
Red
W: White
Y: Yellow
SPECIFICATIONS
ITEM
Bulbs
Fuse
ECT Sensor
resistance
Fuel pump
Headlight (high/low beam)
Brake/tail light
Front turn signal light
Rear turn signal light
License light
Instrument light
Turn signal indicator
High beam indicator
Water temp indicator
Main fuse
Sub fuse
At50°C/122°F
At130°C/266°F
Resistance (20°C/68°F)
Flow capacity
SPECIFICATIONS
12V-35/35W
12V-23/8W
12V-21 W X 2
12V-21 W X 2
12V-5W
12V-1.7WX2
12V-3.4W
LED
LED
15A
10AX2
690 - 860 D
68 - 83 Q
2.6- 3.2 Q.
100 cm
3
(3.4 US oz, 3.5 Imp oz) minimum/minute
TORQUE VALUES
ECT sensor
TOOLS
10 N-m (1.0 kgfm, 7 Ibf-ft)
Apply sealant to the threads
(Do not apply to the sensor head)
Peak voltage adaptor
07HGJ-0020100
with commercially available digital
multimeter (impedance 10 MQ/DCV
minimum)
Ignition Mate peak voltage tester
(U.S.A. only)
18-3