CYLINDER HEAD/VALVES
Install the valve shims in their original locations.
Turn the tensioner shaft clockwise with the special
tool to hold the tensioner in the fully retracted posi-
tion.
TOOL:
Cam chain tensioner stopper
070MG-0010100 or
07AMG-001A100
(U.S.A. only)
Install a new gasket into the cam chain tensioner
lifter.
Install the cam chain tensioner onto the cylinder and
tighten the bolts securely.
'02 -'05 model: Remove the special tool to cancel the lock of the
tensioner lifter.
Coat a new O-ring with engine oil.
Install and tighten the lifter screw to the specified
torque.
/
TORQUE: 3.9 N-m (0.4 kgf-m, 2.9 Ibfft)
After'05 model: Remove the special tool to cancel the lock of the |
tensioner lifter.
Coat new O-rings with engine oil.
Install new O-rings to the PCV joint and cam chain
tensioner lifter groove.
Install the PCV joint to the cam chain tensioner.
8-21