ALTERNATOR/STARTER
Remove the grommet from the crankcase groove.
Remove the two bolts, clamp and ignition pulse
generator.
Remove the bolts and stator.
Remove the woodruff key from the crankshaft.
INSTALLATION
Clean any oil from the tapered portion of the crank-
shaft and flywheel.
Install the woodruff key in the crankshaft key
groove.
Install the stator and tighten the bolts to the speci-
fied torque.
TORQUE: 12 N m (1.2 kgf-m, 9 Ibf-ft)
Apply sealant to the grommet seating surface and
install it to the crankcase groove properly.
Install the ignition pulse generator and wire clamp
properly as shown.
Tighten the bolts securely.
Route the alternator/starter wires under the guide of
the stator base.
Route and clamp the alternator/starter wire properly
(page 1-14).
Connect the alternator/starter 3P (Bl) and 6P (W)
connectors.
Install the step floor (page 2-9).
11-5