Ignition Coil; Ignition System - Honda Metropolitan CHF50 Service Manual

Hide thumbs Also See for Metropolitan CHF50:
Table of Contents

Advertisement

If the peak voltage measured at the ECM connector
is abnormal, measure the peak voltage at the pulse
generator connector.
Disconnect the alternator/starter 6P (W) connector
and connect the peak voltage tester or adaptor
probes to the connector terminals of the alternator/
starter side.
In the same manner as at the ECM connector, mea-
sure the peak voltage and compare it to the voltage
measured at the ECM connector.
• If the peak voltage measured at the ECM is
abnormal and the one measured at the alterna-
tor/starter is normal, the wire harness has an
open or short circuit, or loose connection.
• If the peak voltage is lower than standard value,
follow the checks described in the troubleshoot-
ing chart (page 16-4).
Install the removed parts in the reverse order of
removal.

IGNITION COIL

REMOVAL/INSTALLATION
Remove the luggage box (page 2-6).
Disconnect the spark plug cap from the plug.
Disconnect the ignition coil primary wire connec-
tors.
Remove the bolt and ignition coil.
Installation is in the reverse order of removal.

IGNITION SYSTEM

6P (W) CONNECTOR
6P (W) CONNECTOR
CONNECTORS
IGNITION COIL
BOLT
16-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Metropolitan chf50pMetropolitan chf50s

Table of Contents